浏览分类
Phoenix Contact ELR H51-IESSC-24DC500AC-9 混合型电机启动器
说明
Phoenix Contact ELR H51-IESSC-24DC500AC-9 混合型电机启动器采用母线安装和螺钉连接。
规格参数
| Brand | Phoenix Contact |
|---|---|
| Model | ELR H51-IESSC-24DC500AC-9 |
| Order Number | 2902745 |
| Leakage current | 0 mA |
| Response time | < 2 s |
| Rated insulation voltage | 500 V |
| Rated surge voltage | 6 kV |
| Switching frequency | ≤ 2 Hz (Load-dependent) |
| Control supply voltage range | 19.2 V DC ... 30 V DC |
| Load current range | 1.5 A ... 9 A (see to derating) |
| Mains frequency | 50/60 Hz |
| Operating voltage range | 42 V AC ... 550 V AC |
| Triggering voltage range | 19.2 V DC ... 30 V DC |
| Degree of protection | IP20 |
| REACH candidate substance (CAS No.) | 1-Methyl-2-pyrrolidone (NMP) (CAS: 872-50-4) |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
| Altitude | ≤ 2000 m |
| Ambient temperature (operation) | -25 °C ... 70 °C (observe derating) |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Category code | NLDX / NRNT |
| Certificate | PTB 12 ATEX 3004 |
| Certificate | NLDX.E228652 |
| Certificate | 2020970304000811 |
| Conductor cross-section AWG | 24 ... 14 |
| Conductor cross-section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section rigid | 0.2 mm² ... 2.5 mm² |
| Connection method | Screw connection |
| Contact switching type | 1 changeover contact |
| Cooling time | 20 min (for auto reset) |
| Coordination type | 2 |
| Degree of pollution | 2 |
| Depth | 114.5 mm |
| ECLASS-13.0 | 27370905 |
| ECLASS-15.0 | 27370905 |
| ECLASS-15.0 ASSET | 27250101 |
| Environment friendly use period (EFUP) | EFUP-50 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. |
| Error indication | Red LED |
| ETIM 10.0 | EC001037 |
| Exemption | 7(a), 7(c)-I |
| Fla | 6.5 A (500 V AC) |
| Flammability rating according to UL 94 (Housing) | V0 (Housing) |
| Fulfills EU RoHS substance requirements | Yes |
| Group installation | 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) |
| Group installation | 30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) |
| Height | 160 mm |
| Identification | II (2) G [Ex e] [Ex d] [Ex px] |
| Identification | II (2) D [Ex t] [Ex p] |
| Identification | ≤ 3 |
| Identification | 2 |
| Identification | e |
| Identification | GB/T 14048.6-2016 |
| Input name | Control input right/left |
| Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit | Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC |
| Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit | Safe isolation (EN 50178) at operating voltage ≤ 300 V AC |
| Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit | Basic insulation (IEC 60947-1) at operating voltage 300 V AC ... 500 V AC |
| Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit | Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC |
| Isolation characteristics between the control input and control supply voltage to auxiliary circuit | Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
| Isolation characteristics between the control input and control supply voltage to auxiliary circuit | Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC |
| Maximum power dissipation | 12 W |
| Maximum power dissipation for nominal condition | 11 W |
| Minimum order quantity | 1 pc |
| Minimum power dissipation | 0.88 W |
| Motor starter type | Reversing starter |
| Mounting position | vertical (horizontal DIN rail, motor output below) |
| Mounting type | Bus bar mounting |
| Mounting type | DIN rail mounting |
| Number of phases | 3 |
| Operate threshold | > 45 A |
| Operating mode | 100% operating factor |
| Operating voltage display | Green LED |
| Overvoltage category | III |
| Packing unit | 1 pc |
| Product key | DK7454 |
| Product type | Hybrid motor starters |
| Protective circuit | Surge protection |
| Protective circuit | Reverse polarity protection; Parallel polarity protection diode |
| Protective circuit | Reverse polarity protection |
| Protective circuit | Surge protection; Varistor |
| Protective circuit | Short-circuit protection; Fuse |
| Rated actuating current I C | 5 mA |
| Rated actuating voltage U C | 24 V DC |
| Rated control circuit supply voltage U S | 24 V DC |
| Rated control supply current I S | 40 mA |
| Rated operating voltage U e | 500 V AC |
| Sccr | 100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
| SCCR | 5 kA (500 V AC (fuse: 20 A RK5 (standard fault))) |
| Scip | 3bb8249d-06af-482f-a35b-ffe197ab31a3 |
| Screw thread | M3 |
| Standards/regulations | IEC 60947-1 |
| Standards/regulations | EN 60947-4-2 |
| Standards/regulations | IEC 61508 |
| Standards/regulations | ISO 13849 |
| Status display | LED (yellow) |
| Stripping length | 8 mm |
| Switching capacity in accordance with IEC 60947-5-1 | 3 A (230 V, AC 15) |
| Switching capacity in accordance with IEC 60947-5-1 | 2 A (24 V (DC 13)) |
| Switching level | < 5 V DC (For EMERGENCY STOP) |
| Switching threshold | 9.6 V (“0” signal) |
| Switching threshold | 19.2 V (“1” signal) |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Tightening torque | 5 lb f -in. ... 7 lb f -in. |
| Trigger characteristic in acc. with IEC 60947-4-2 | Class 10A |
| Typical turn-off time | < 30 ms |
| UNSPSC 21.0 | 25173900 |
| Weight per piece (excluding packing) | 350 g |
| Weight per piece (including packing) | 432.45 g |
| Width | 22.5 mm |