Phoenix Contact QUINT4-PS/1AC/12DC/7.5/PT fonte de alimentação
Descricao
Phoenix Contact QUINT4-PS/1AC/12DC/7.5/PT integra a linha QUINT POWER como fonte de alimentação. Fornece saída nominal de 12 V DC. O produto é montado em trilho DIN e tem grau de proteção IP20.
Especificacoes
| Brand | Phoenix Contact |
|---|---|
| Model | QUINT4-PS/1AC/12DC/7.5/PT |
| Order Number | 2904607 |
| Voltage | 10 V (Test Level 3) |
| Frequency | 16.67 Hz |
| Current | 7.5 A |
| Inrush current | typ. 11.4 A (at 25 °C) |
| Nominal output voltage | 12 V DC |
| Power loss nominal load max. | < 8.1 W (120 V AC) |
| Power loss nominal load max. | < 7.1 W (230 V AC) |
| Standard – Safety extra-low voltage | IEC 61010-1 (SELV) |
| Typical national grid voltage | 120 V AC |
| Voltage type of supply voltage | AC |
| Switching frequency | 4.00 kHz ... 70.00 kHz (Auxiliary converter stage) |
| Frequency range | 0 kHz ... 2 kHz |
| Input voltage range | 100 V AC ... 240 V AC -15 % ... +10 % |
| Degree of protection | IP20 |
| Recommended breaker for input protection | 6 A ... 16 A (Characteristic B, C or comparable) |
| Vibration (operation) | < 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6) |
| EMC requirements for noise emission | EN 61000-6-3 |
| EMC requirements for noise emission | EN 61000-6-4 |
| EMC requirements for noise immunity | EN 61000-6-1 |
| EMC requirements for noise immunity | EN 61000-6-2 |
| EMC requirements for power supply | IEC 61850-3 (G,H) |
| EMC requirements for power supply | EN 61000-6-5 (switching devices) |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
| Additional text | 120 V AC |
| Additional text | 230 V AC |
| Additional text | 60 s |
| Additional text | 3 s |
| Additional text | DC, 60 s |
| Additional text | Test Level 2 |
| Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| Ambient temperature (start-up type tested) | -40 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Climatic class | 3K3 (in acc. with EN 60721) |
| CO2e kg | 10.764 kg CO2e |
| Comments | Criterion A |
| Comments | Criterion B |
| Conductor cross-section AWG max. | 14 |
| Conductor cross-section AWG min. | 24 |
| Conductor cross-section flexible max. | 2.5 mm² |
| Conductor cross-section flexible min. | 0.2 mm² |
| Conductor cross-section, rigid max. | 2.5 mm² |
| Conductor cross-section, rigid min. | 0.2 mm² |
| Connection in parallel | yes, for redundancy and increased capacity |
| Connection in series | yes |
| Connection method | Push-in connection |
| Contact discharge | 8 kV (Test Level 4) |
| Control deviation | < 0.3 % (Static load change 10 % ... 90 %) |
| Control deviation | < 3 % (Dynamic load change 10 % ... 90 %, (10 Hz)) |
| Control deviation | < 0.1 % (change in input voltage ±10 %) |
| Crest factor | typ. 1.57 (120 V AC) |
| Crest factor | typ. 1.67 (230 V AC) |
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Criterion C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
| Current consumption | 1 A (100 V AC) |
| Current consumption | 0.85 A (120 V AC) |
| Current consumption | 0.46 A (230 V AC) |
| Current consumption | 0.44 A (240 V AC) |
| Current consumption | 0.92 A (110 V DC) |
| Current consumption | 0.4 A (250 V DC) |
| Default | 12 V DC 24 mA 12 V DC for U Out > 0.9 x U Set |
| Degree of pollution | 2 |
| Depth | 90 mm |
| Digital | 0 V DC 12 V DC 24 mA |
| Discharge current to PE | < 0.25 mA (264 V AC, 60 Hz) |
| Discharge current to PE | < 0.17 mA |
| Discharge in air | 15 kV (Test Level 4) |
| Dynamic Boost (I Dyn.Boost ) | 12.75 A (≤ 60 °C (5 s)) |
| ECLASS-13.0 | 27040701 |
| ECLASS-15.0 | 27040701 |
| Efficiency | typ. 91.5 % (120 V AC) |
| Efficiency | typ. 92.5 % (230 V AC) |
| Electric strength, max. | 300 V AC 60 s |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| ETIM 10.0 | EC002540 |
| Exemption | 7(a), 7(c)-I |
| Feedback voltage resistance | ≤ 25 V DC |
| Frequency | 50 Hz |
| Frequency | 60 Hz |
| Frequency | 0 Hz |
| Frequency range | 80 MHz ... 1 GHz |
| Frequency range | 1 GHz ... 6 GHz |
| Frequency range | 0.15 MHz ... 80 MHz |
| Frequency range | 50 Hz ... 60 Hz |
| Frequency range (f N ) | 50 Hz ... 60 Hz -10 % ... +10 % |
| Fulfills EU RoHS substance requirements | Yes |
| Fuse protection (secondary side) | electronic |
| Height | 106 mm |
| Hood version | Polycarbonate |
| Housing material | Plastic |
| Input | 4 kV (Test Level 4 - asymmetrical) |
| Input | 2 kV (Test Level 4 - symmetrical) |
| Input | 2 kV (symmetrical) |
| Input | 4 kV (asymmetrical) |
| Input fuse | 3.15 A (slow-blow, internal) |
| Input voltage range | 110 V DC ... 250 V DC -20 % ... +40 % |
| Input/output/signal | asymmetrical |
| Inrush current integral (I 2 t) | < 0.2 A 2 s |
| Inrush current limitation | < 11.4 A |
| Installation distance right/left (active) | 15 mm / 15 mm (P Out ≥50% ) |
| Installation distance right/left (active, passive) | 0 mm / 0 mm (P Out ≤50 %) |
| Installation distance right/left (passive) | 5 mm / 5 mm (P Out ≥50% ) |
| Installation distance top/bottom (active) | 30 mm / 30 mm (P Out ≥50% ) |
| Installation distance top/bottom (active, passive) | 30 mm / 30 mm (P Out ≤50 %) |
| Installation distance top/bottom (passive) | 30 mm / 30 mm (P Out ≥50% ) |
| Insulation voltage input/output | 4 kV AC (type test) |
| Insulation voltage input/output | 3 kV AC (routine test) |
| Mains buffering time | typ. 48 ms (120 V AC) |
| Mains buffering time | typ. 48 ms (230 V AC) |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Maximum altitude | ≤ 5000 m (> 2000 m, observe derating) |
| Maximum no-load power dissipation | < 0.6 W (230 V AC) |
| Maximum no-load power dissipation | < 0.6 W (120 V AC) |
| Minimum order quantity | 1 pc |
| Mounting type | DIN rail mounting |
| MTBF (IEC 61709, SN 29500) | > 1221000 h (25 °C) |
| MTBF (IEC 61709, SN 29500) | > 671000 h (40 °C) |
| MTBF (IEC 61709, SN 29500) | > 248000 h (60 °C) |
| No-load proof | yes |
| Nominal output current (I N ) | 7.5 A |
| Nominal power consumption | 96.3 VA |
| Number of periods | 0.5 / 1 / 30 periods |
| Number of periods | 5 / 10 / 50 periods |
| Number of periods | 0.5 / 1 / 5 / 50 periods |
| Number of phases | 1 |
| Output | 4 kV (Test Level 4 - asymmetrical) |
| Output | 1 kV (Test Level 3 - symmetrical) |
| Output | 2 kV (Test Level 3 - asymmetrical) |
| Output power | 90 W |
| Output power | 150 W |
| Overvoltage category (EN 61010-1) | II (≤ 5000 m) |
| Overvoltage category (EN 62477-1) | III (≤ 2000 m) |
| P Out | > P Thr (LED lights up yellow, output power > P Thr, depending on the rotary selector switch setting) |
| Packing unit | 1 pc |
| Product key | CMPI12 |
| Product type | Power supply |
| Protection against overvoltage at the output (OVP) | ≤ 18 V DC |
| Protection class | II |
| Protective circuit | Transient surge protection; Varistor |
| Residual ripple | < 35 mV PP (with nominal values) |
| Rise time | 50 ms (U Out = 10 % ... 90 %) |
| Scip | 0c7ace05-b5de-466f-8ef2-05caf4801fbd |
| Setting range of the output voltage (U Set ) | 12 V DC ... 15 V DC (constant capacity) |
| Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Short-circuit-proof | yes |
| Signal | 4 kV (Test Level 4 - asymmetrical) |
| Signal | 0.5 kV (Test Level 2 - symmetrical) |
| Signal | 1 kV (Test Level 2 - asymmetrical) |
| Single conductor/terminal point, stranded, with ferrule, max. | 2.5 mm² |
| Single conductor/terminal point, stranded, with ferrule, min. | 0.25 mm² |
| Siq | CB-Scheme (IEC 61010-1, IEC 61010-2-201) |
| Standard - Safe isolation | IEC 61558-2-16 |
| Standard - Safe isolation | IEC 61010-2-201 |
| Standard - safety for equipment for measurement, control, and laboratory use | IEC 61010-1 |
| Standard - safety for equipment for measurement, control, and laboratory use | IEC 61010-2-201 (SELV) |
| Standard - Safety of transformers | EN 61558-2-16 |
| Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
| Standard – Safety extra-low voltage | IEC 61010-2-201 (PELV) |
| Standards/regulations | EN 55016 |
| Standards/regulations | EN 61000-6-3 (Class B) |
| Standards/regulations | Additional basic standard EN 61000-6-5 (immunity in switching devices), IEC/EN 61850-3 (power supply) |
| Standards/regulations | EN 61000-3-2 |
| Standards/regulations | EN 61000-3-2 (Class A) |
| Standards/regulations | EN 61000-3-3 |
| Standards/regulations | EN 61000-4-2 |
| Standards/regulations | EN 61000-4-3 |
| Standards/regulations | EN 61000-4-4 |
| Standards/regulations | EN 61000-4-5 |
| Standards/regulations | EN 61000-4-6 |
| Standards/regulations | EN 61000-4-8 |
| Standards/regulations | EN 61000-4-11 |
| Standards/regulations | EN 61000-4-9 |
| Standards/regulations | EN 61000-4-12 |
| Standards/regulations | EN 61000-4-16 |
| Standards/regulations | EN 61000-4-18 |
| Stripping length | 10 mm |
| Switching frequency | 80.00 kHz ... 190.00 kHz (Main converter stage) |
| Switching frequency | 30.00 kHz ... 150.00 kHz (PFC stage) |
| Temperature | 40 °C |
| Temperature | 25 °C |
| Temperature code | T4 (-25 ... +70 °C; > 60 °C, Derating: 2,5 %/K) |
| terminal blocks) | V0 |
| Test field strength | 20 V/m (Test Level 3) |
| Test field strength | 10 V/m (Test Level 3) |
| Test field strength | 100 A/m |
| Test field strength | 1 kA/m |
| Test field strength | 300 A/m |
| Test field strength | 1000 A/m |
| Test level 1 | 16.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3) |
| Test level 2 | 16.67 Hz 50 Hz 60 Hz (Test Level 2) |
| Time | 96000 h |
| Time | 145000 h |
| Time | 280000 h |
| Time | 430000 h |
| Type of housing | Polycarbonate |
| Types of signaling | LED |
| Typical national grid voltage | 230 V AC |
| Typical response time | 300 ms |
| U Out | > 0.9 x U Set (LED lights up green) |
| U Out | < 0.9 x U Set (LED flashes green) |
| UL approvals | UL Listed UL 61010-1 |
| UL approvals | UL Listed UL 61010-2-201 |
| UL approvals | UL 121201 & CSA C22.2 No. 213-17 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) |
| UNSPSC 21.0 | 39121000 |
| Voltage | 100 V AC |
| Voltage | 30 V (10 s) |
| Voltage | 300 V (1 s) |
| Voltage | 1 kV (symmetrical) |
| Voltage | 2.5 kV (asymmetrical) |
| Voltage dip | 70 % |
| Voltage dip | 40 % |
| Voltage dip | 0 % |
| Voltage type of supply voltage | DC |
| Weight per piece (excluding packing) | 307 g |
| Weight per piece (including packing) | 384.6 g |
| Width | 45 mm |
| With protective coating | no |