O módulo inversor B&R 8BVI0055HCSS.000-1 fornece duas saídas de 24 VDC.

Especificacoes

Brand B&R
MPN 8BVI0055HCSS.000-1
Max. power consumption per encoder interface P SMC [W] = 19 V * I Encoder [A]
Input current at nominal voltage Approx. 10 mA
Max. output frequency 598 Hz
Input voltage 25 VDC ±1.6%
Output voltage Typ. 12.5 V
Output voltage 24 VDC +5.8% / -0%
Peak current 18.9 A eff
Max. switching frequency 0.5 Hz
Nominal switching frequency 5 kHz
Resistance range 500 Ω to 5 kΩ
Cold plate mounting 0.65 A/K (starting at 57°C)
Cold plate mounting 0.28 A/K (starting at 46°C)
Cold plate mounting 0.14 A/K (starting at 5°C)
Fuse protection 250 mA (slow-blow) electronic, automatic reset
Overload and short-circuit protection Yes
Overload protection Yes
Pass-through mounting 209 mm
Pass-through mounting No reduction
Pass-through mounting 0.15 A/K (starting at 34°C)
Pass-through mounting 0.08 A/K (starting at -33°C)
Short-circuit and ground fault protection Yes
Weight Approx. 2.2 kg
B&R ID code 0xAA14
CE Yes
Circuit Sink
Cold plate 212 mm
Connections 9-pin female DSUB connector
Continuous current per connection 1.1 A
Continuous current per motor connection 7.6 A eff
Continuous power consumption 5.6 kW
Continuous power per motor connection 5.5 kW
Cooling and mounting type Cold plate or pass-through mounting
CRA (Cyber Resilience Act) Evaluation ongoing
CSA 28 to 10
Data transfer rate 6.25 Mbit/s
DC bus capacitance 165 µF
DC bus voltage (U DC ) 25 VDC * (U DC /315)
DC bus voltage (U DC ) 24 VDC ±6%
Discharge capacitance 0.14 µF
Dynamic node allocation (DNA) Yes
Encoder - ACOPOSmulti No
Encoder monitoring Yes
Extinction potential Approx. 30 V
Falling edge 53 µs ±0.5 µs (digitally filtered)
Functional safety Yes (openSAFETY)
Hanging vertically Yes
Height 317 mm
High >15 V
Horizontal, face up Yes
Input - Input Yes
Input - Inverter module Yes
Input capacitance 23.5 µF
Installation elevation above sea level IP20
Installation elevation above sea level 2 (non-conductive pollution)
Installation elevation above sea level III
KC Yes
Load capacity 350 mA
Max. encoder cable length 100 m Depends on the cross section of the power supply wires in the encoder cable
Max. extinction energy per switching operation 1.5 Ws
Max. internal resistance 0.5 Ω
Max. motor line length depending on switching frequency 25 m
Max. motor line length depending on switching frequency 25 m
Max. motor line length depending on switching frequency 10 m
Max. motor line length depending on switching frequency Limit value curve A
Max. power consumption 18 W + P SMC1 + P SLOT2 + P 24 V Out + P HoldingBrake
Maximum 55°C
Maximum 30 VDC
Maximum 4000 m
Modulation compared to ground potential Max. ±38 V
Module width 1
Nominal 750 VDC
Nominal 5 to 40°C
Nominal 24 VDC
Nominal 0 to 500 m
Nominal losses in standby mode 8.3 W
Open-circuit monitoring Yes
Operation 5 to 85%
Overload-proof Yes
Possible switching frequencies 5 / 10 / 20 kHz
Power dissipation depending on switching frequency [0.6 * I M ² + 1.3 * I M + 60] W
Power dissipation depending on switching frequency [0.97 * I M ² + 0.5 * I M + 110] W
Power dissipation depending on switching frequency [1.7 * I M ² - 0.7 * I M + 225] W
Power dissipation relative to continuous apparent power IE2 (10,25) 2.4% IE2 (50,25) 2.4% IE2 (10,50) 2.7% IE2 (50,50) 2.7% IE2 (90,50) 2.7% IE2 (10,100) 3.2% IE2 (50,100) 3.2% IE2 (90,100) 3.2%
Quantity 2
Quantity 1
Quantity 2
Quantity 1
Quantity 1
Quantity 1
Reduction of continuous current depending on installation elevation 0.76 A eff per 1000 m
Response threshold for open-circuit monitoring Approx. 0.25 A
Response threshold for undervoltage monitoring 24 VDC -2% / -4%
Rising edge 52 µs ±0.5 µs (digitally filtered)
Shield connection Yes
Short-circuit proof Yes
Signal transmission RS485
Slots for plug-in modules 2
Standing horizontally No
Status indicators UP/DN LEDs
Storage -25 to 55°C
Storage 5 to 95%
Terminal cable cross section dimension of shield connection 12 to 22 mm
Transport -25 to 70°C
Transport Max. 95% at 40°C
Type EnDat 2.2
U, V, W, PE Connector
UKCA Yes
UL cULus E225616 Power conversion equipment
UL/C-UL-US 30 to 10
Undervoltage monitoring Yes
Variant ACOPOSmulti backplane
Variant ACOPOSmulti backplane
Width 53 mm