カテゴリを見る
B&R 8BVI0055HCSS.000-1 インバータモジュール
説明
B&R 8BVI0055HCSS.000-1 インバータモジュールは 24 VDC 出力を 2 系統備えています。
仕様
| Brand | B&R |
|---|---|
| MPN | 8BVI0055HCSS.000-1 |
| Max. power consumption per encoder interface | P SMC [W] = 19 V * I Encoder [A] |
| Input current at nominal voltage | Approx. 10 mA |
| Max. output frequency | 598 Hz |
| Input voltage | 25 VDC ±1.6% |
| Output voltage | Typ. 12.5 V |
| Output voltage | 24 VDC +5.8% / -0% |
| Peak current | 18.9 A eff |
| Max. switching frequency | 0.5 Hz |
| Nominal switching frequency | 5 kHz |
| Resistance range | 500 Ω to 5 kΩ |
| Cold plate mounting | 0.65 A/K (starting at 57°C) |
| Cold plate mounting | 0.28 A/K (starting at 46°C) |
| Cold plate mounting | 0.14 A/K (starting at 5°C) |
| Fuse protection | 250 mA (slow-blow) electronic, automatic reset |
| Overload and short-circuit protection | Yes |
| Overload protection | Yes |
| Pass-through mounting | 209 mm |
| Pass-through mounting | No reduction |
| Pass-through mounting | 0.15 A/K (starting at 34°C) |
| Pass-through mounting | 0.08 A/K (starting at -33°C) |
| Short-circuit and ground fault protection | Yes |
| Weight | Approx. 2.2 kg |
| B&R ID code | 0xAA14 |
| CE | Yes |
| Circuit | Sink |
| Cold plate | 212 mm |
| Connections | 9-pin female DSUB connector |
| Continuous current per connection | 1.1 A |
| Continuous current per motor connection | 7.6 A eff |
| Continuous power consumption | 5.6 kW |
| Continuous power per motor connection | 5.5 kW |
| Cooling and mounting type | Cold plate or pass-through mounting |
| CRA (Cyber Resilience Act) | Evaluation ongoing |
| CSA | 28 to 10 |
| Data transfer rate | 6.25 Mbit/s |
| DC bus capacitance | 165 µF |
| DC bus voltage (U DC ) | 25 VDC * (U DC /315) |
| DC bus voltage (U DC ) | 24 VDC ±6% |
| Discharge capacitance | 0.14 µF |
| Dynamic node allocation (DNA) | Yes |
| Encoder - ACOPOSmulti | No |
| Encoder monitoring | Yes |
| Extinction potential | Approx. 30 V |
| Falling edge | 53 µs ±0.5 µs (digitally filtered) |
| Functional safety | Yes (openSAFETY) |
| Hanging vertically | Yes |
| Height | 317 mm |
| High | >15 V |
| Horizontal, face up | Yes |
| Input - Input | Yes |
| Input - Inverter module | Yes |
| Input capacitance | 23.5 µF |
| Installation elevation above sea level | IP20 |
| Installation elevation above sea level | 2 (non-conductive pollution) |
| Installation elevation above sea level | III |
| KC | Yes |
| Load capacity | 350 mA |
| Max. encoder cable length | 100 m Depends on the cross section of the power supply wires in the encoder cable |
| Max. extinction energy per switching operation | 1.5 Ws |
| Max. internal resistance | 0.5 Ω |
| Max. motor line length depending on switching frequency | 25 m |
| Max. motor line length depending on switching frequency | 25 m |
| Max. motor line length depending on switching frequency | 10 m |
| Max. motor line length depending on switching frequency | Limit value curve A |
| Max. power consumption | 18 W + P SMC1 + P SLOT2 + P 24 V Out + P HoldingBrake |
| Maximum | 55°C |
| Maximum | 30 VDC |
| Maximum | 4000 m |
| Modulation compared to ground potential | Max. ±38 V |
| Module width | 1 |
| Nominal | 750 VDC |
| Nominal | 5 to 40°C |
| Nominal | 24 VDC |
| Nominal | 0 to 500 m |
| Nominal losses in standby mode | 8.3 W |
| Open-circuit monitoring | Yes |
| Operation | 5 to 85% |
| Overload-proof | Yes |
| Possible switching frequencies | 5 / 10 / 20 kHz |
| Power dissipation depending on switching frequency | [0.6 * I M ² + 1.3 * I M + 60] W |
| Power dissipation depending on switching frequency | [0.97 * I M ² + 0.5 * I M + 110] W |
| Power dissipation depending on switching frequency | [1.7 * I M ² - 0.7 * I M + 225] W |
| Power dissipation relative to continuous apparent power | IE2 (10,25) 2.4% IE2 (50,25) 2.4% IE2 (10,50) 2.7% IE2 (50,50) 2.7% IE2 (90,50) 2.7% IE2 (10,100) 3.2% IE2 (50,100) 3.2% IE2 (90,100) 3.2% |
| Quantity | 2 |
| Quantity | 1 |
| Quantity | 2 |
| Quantity | 1 |
| Quantity | 1 |
| Quantity | 1 |
| Reduction of continuous current depending on installation elevation | 0.76 A eff per 1000 m |
| Response threshold for open-circuit monitoring | Approx. 0.25 A |
| Response threshold for undervoltage monitoring | 24 VDC -2% / -4% |
| Rising edge | 52 µs ±0.5 µs (digitally filtered) |
| Shield connection | Yes |
| Short-circuit proof | Yes |
| Signal transmission | RS485 |
| Slots for plug-in modules | 2 |
| Standing horizontally | No |
| Status indicators | UP/DN LEDs |
| Storage | -25 to 55°C |
| Storage | 5 to 95% |
| Terminal cable cross section dimension of shield connection | 12 to 22 mm |
| Transport | -25 to 70°C |
| Transport | Max. 95% at 40°C |
| Type | EnDat 2.2 |
| U, V, W, PE | Connector |
| UKCA | Yes |
| UL | cULus E225616 Power conversion equipment |
| UL/C-UL-US | 30 to 10 |
| Undervoltage monitoring | Yes |
| Variant | ACOPOSmulti backplane |
| Variant | ACOPOSmulti backplane |
| Width | 53 mm |
| With wire end sleeve | 0.25 to 4 mm² |