Skip to content

WAGO 750-346 DeviceNet Fieldbus Coupler - Used

WAGO 750-346 DeviceNet Fieldbus Coupler - Used

Request a Quote

Tell us what you need and we will follow up about availability and pricing.

Start request

Description

Used WAGO 750-346 DeviceNet fieldbus coupler, removed from equipment.

Specifications

Brand WAGO
Model 750-346
MPN 750-346
AWG 28-14
ECCN NO US CLASSIFICATION
Color light gray
Depth 71.9 mm / 2.831 inches
Width 49.5 mm / 1.949 inches
CAS-No. 12060-00-3; 1303-86-2; 1317-36-8; 7439-92-1; 79-94-7; 80-43-3
Height 96.8 mm / 3.811 inches
PU (SPU) 1 pcs
UNSPSC 32,151,705
Weight 115 g
Variant ECO
ETIM 9.0 EC001603
ETIM 10.0 EC001603
Fire load 1.719 MJ
eCl@ss 9.0 27-24-26-07
eCl@ss 10.0 27-24-26-07
Product Type Fieldbus Coupler
Strip length 5 … 6 mm / 0.2 … 0.24 inches
Mounting type DIN-35 rail
Communications DeviceNet
Product Family WAGO I/O System 750/753
Connection type System supply
Protection type IP20
Solid conductor 0.08 … 1.5 mm² / 28 … 16 AWG
Housing material Polycarbonate; polyamide 6.6
Pollution degree 2 per IEC 61131-2
Shock resistance 15g per IEC 60068-2-27
Fieldbus Protocol DeviceNet
max. surround temp. 55°C
Mounting position Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Transmission rate 500 kBd (125 kBd, 250 kBd, 500 kBd)
Conformity marking CE
Operating altitude 0 … 2000 m / 0 … 6562 ft
Number of I/O points 6,000
Vibration resistance Per IEC 60068-2-6
Supply voltage (system) 24 VDC, SELV/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP® connection); External fuse required: 2 A slow-blow
Bus segment length (max.) 500 m
Exposure to pollutants per IEC 60068-2-42 and IEC 60068-2-43
RoHS Compliance Status Compliant,With Exemption
Fine-stranded conductor 0.08 … 1.5 mm² / 28 … 16 AWG
Ambient temperature (storage) -25 … +85 °C
Total current (system supply) 650 mA
EMC emission of interference per EN 61000-6-4
EMC immunity to interference per EN 61000-6-2
Ambient temperature (operation) 0 … +55 °C
Number of modules per node (max.) 64
REACH Candidate List Substance 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol; Diboron trioxide; Lead; Lead monoxide; Lead titanium oxide (PbTiO3); Peroxide, bis(1-methyl-1-phenylethyl)
Connectable conductor materials Copper
Current consumption (system supply) 350 mA
Depth from upper-edge of DIN-rail 64.7 mm / 2.547 inches
SCIP notification number (Bulgaria) 755a7b48-5e26-452d-b5bf-f0e16bcfa2cc
Connection technology 4 x CAGE CLAMP®
Input current (typ.) at nominal load (24 V) 260 mA
Number of fieldbus nodes on master (max.) 64
Relative humidity (without condensation) 95 %
SCIP notification number (Czech Republic) a2d45a90-17ff-49eb-9603-f02ee9c1446c
Connection technology 1 x Male connector; 4-pole
Transmission medium (communication/fieldbus) Shielded Cu cable; Remote bus cable: 2 x 0.82 mm² + 2 x 1.7 mm²; Drop cable: 2 x 0.2 mm² + 2 x 0.32 mm²
Input and output process image (fieldbus) max. 32 bytes/32 bytes
Connection technology DeviceNet: 1 x Male connector; 5-pole
Input current via DeviceNet interface at 11 V 120 mA
Number of modules without a bus extension (max.) 64
Power supply efficiency (typ.) at nominal load (24 V) 80 %
Permissible SO2 contaminant concentration at a relative humidity < 75 % 25 ppm
Permissible H2S contaminant concentration at a relative humidity < 75 % 10 ppm