Aller au contenu

Contrôleur de déplacement laser Keyence LK-G3001 - d'occasion

Contrôleur de déplacement laser Keyence LK-G3001 - d'occasion

Demander un devis

Quantite, etat et destination.

Demander un devis

Description

Contrôleur de déplacement laser Keyence LK-G3001 d'occasion, retiré d’un équipement, avec des traces d’usure visibles.

Specifications

Brand Keyence
Model LK-G3001
RS-232C interface Measured data output and control input/output (Maximum baud rate: 115,200 bps, selectable)
Power voltage 24 VDC ±10 %, Ripple (P-P) ≤10 %
Display range ±9,999.99 mm to ±9,999.99 µm (Selectable from six levels)
USB interface In conformity with USB Revision 2.0 Full speed (USB1.1 compatible)
Weight Approx. 370 g
Ambient temperature 0 to +50 °C (32 to 122 °F)
Relative humidity 35 to 85 % RH (No condensation)
Alarm output For OUT1, NPN open-collector output (N.C.)
Alarm output For OUT2, NPN open-collector output (N.C.)
Analog current output 4 to 20 mA x 2 outputs, maximum load resistance: 350 Ω
Analog voltage output ±10 V x 2 outputs, output impedance: 100 Ω
Binary output Measured data output (21 bits), OUT1/OUT2 selectable, NPN open-collector output
Binary selector output Binary selector input
Comparator output For OUT1, NPN open-collector output
Comparator output For OUT2, NPN open-collector output
Current consumption ≤500 mA with 1 head/≤600 mA with 2 heads
Head compatibility All LK-G sensor heads are compatible
Laser remote interlock input Non-voltage input
Laser-Off input For Head A/Head B, non-voltage input
Major functions 2 OUT simultaneous measurement, Operation, Averaging, Filter, Calibration, Measurement, AUTO ZERO, Sampling frequency setting, Mutual interference prevention, Data storage, 8-program memory, ECO mode, ABLE setting, Target setting, ABLE tuning, Selection of measurement surface of transparent target, Statistics processing, Connection of setting support software, Selectable head-mounting, etc.
Minimum display unit 0.01 µm
Number of connectable sensors Maximum of 2 units
Program switching input Non-voltage input x 3 inputs
Refresh rate 10 times/sec
Reset input Auto-zero input
Reset input Auto-zero input
Strobe output NPN open-collector output
Timing input For OUT1, non-voltage input
Timing input For OUT2, non-voltage input
Type Separate monitor model