Phoenix Contact TRIO-PS-2G/3AC/24DC/20 2903155 Stromversorgung - Gebraucht
Beschreibung
Gebrauchte Phoenix Contact TRIO-PS-2G/3AC/24DC/20 Stromversorgung, Bestellnummer 2903155. Sie nimmt 3-phasige 400–500 V AC Eingang auf und liefert 24 V DC Ausgang bei 20 A, mit einer maximalen Leistung von 480 W. Das Gerät wurde aus einer Anlage ausgebaut und zeigt minimale Gebrauchsspuren.
Spezifikationen
| Brand | Phoenix Contact |
|---|---|
| Model | TRIO-PS-2G/3AC/24DC/20 |
| Order Number | 2903155 |
| HS Code | 850440 |
| Voltage | 10 V (Test Level 3) |
| Frequency | 50 Hz |
| Output Current | 20 A |
| Continuous load current | 100 mA |
| Inrush current | ≤ 22 A (typical) |
| Nominal output voltage | 24 V DC ±1 % |
| Power factor | 0.63 |
| Power loss nominal load max. | < 38 W (480 V AC) |
| Standard – Safety extra-low voltage | IEC 62368-1 (SELV) und EN 60204-1 (PELV) |
| Typical national grid voltage | 3x 400 V AC |
| Voltage type of supply voltage | AC |
| AC frequency range | 50 Hz ... 60 Hz |
| Frequency range | Class A, B |
| Input Frequency | 50-60 Hz |
| Input voltage range | 3x 400 V AC ... 500 V AC -20 % ... +15 % |
| Nominal input voltage range | 3x 400 V AC ... 500 V AC |
| Degree of protection | IP20 |
| Recommended breaker for input protection | 6 A ... 16 A (Characteristics B, C, D, K) |
| Startup Temperature | -40°C / -40°F startup (type tested) |
| Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
| Vibration (operation) | 15 Hz ... 150 Hz, 4g, 90 min. |
| EMC requirements for noise emission | EN 61000-6-3 |
| EMC requirements for noise emission | EN 61000-6-4 |
| EMC requirements for noise immunity | EN 61000-6-1 |
| EMC requirements for noise immunity | EN 61000-6-2 |
| REACH candidate substance (CAS No.) | Diboron trioxide (CAS: 1303-86-2) |
| REACH candidate substance (CAS No.) | Lead monoxide (lead oxide) (CAS: 1317-36-8) |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
| Shipbuilding approval | GL applied for |
| 13/14 | U OUT > 0.9 x U N (U N = 24 V DC) |
| Additional text | Test Level 2 |
| Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| Ambient temperature (start-up type tested) | -40 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Climatic class | 3K3 (in acc. with EN 60721) |
| CO2e kg | 40.66 kg CO2e |
| Color | green |
| Comments | Criterion A |
| Comments | Criterion B |
| Conductor cross-section AWG max. | 12 |
| Conductor cross-section AWG max. | 8 |
| Conductor cross-section AWG max. | 16 |
| Conductor cross-section AWG min. | 24 |
| Conductor cross-section flexible max. | 2.5 mm² |
| Conductor cross-section flexible max. | 6 mm² |
| Conductor cross-section flexible max. | 1.5 mm² |
| Conductor cross-section flexible min. | 0.2 mm² |
| Conductor cross-section, rigid max. | 4 mm² |
| Conductor cross-section, rigid max. | 10 mm² |
| Conductor cross-section, rigid max. | 1.5 mm² |
| Conductor cross-section, rigid min. | 0.2 mm² |
| Connection in parallel | yes, for redundancy and increased capacity |
| Connection in series | yes |
| Connection method | Push-in connection |
| Contact discharge | 6 kV (Test Level 4) |
| Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
| Control deviation | < 3 % (Dynamic load change 10 % ... 90 %, 10 Hz) |
| Control deviation | < 0.1 % (change in input voltage ±10 %) |
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Current consumption | 3x 1.2 A (400 V AC) |
| Current consumption | 3x 1 A (500 V AC) |
| Current consumption | 2x 2.3 A (400 V AC) |
| Current consumption | 2x 1.9 A (500 V AC) |
| DC OK | U OUT > 0.9 x U N (U N = 24 V DC) |
| Default | closed |
| Degree of pollution | 2 |
| Depth | 160 mm |
| Derating | > 60 °C ... 70 °C (2.5 %/K) |
| Digital | 30 V AC 30 V DC 100 mA |
| Discharge current to PE | < 3.5 mA |
| Discharge current to PE | < (550 V AC, 60 Hz) |
| Discharge in air | 8 kV (Test Level 4) |
| Dynamic Boost | 30A (5s) |
| Dynamic Boost (I Dyn.Boost ) | 30 A (5 s) |
| ECLASS-13.0 | 27040701 |
| ECLASS-15.0 | 27040701 |
| Efficiency | > 91.5 % (400 V AC) |
| Efficiency | typ. 91.8 % (480 V AC) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Emitted radio interference in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
| Environment friendly use period (EFUP) | EFUP-25 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. |
| ETIM 10.0 | EC002540 |
| Exemption | 7(a), 7(c)-I |
| Frequency range | 0 kHz ... 2 kHz |
| Frequency range | 80 MHz ... 6 GHz |
| Frequency range | 0.15 MHz ... 80 MHz |
| Fulfills EU RoHS substance requirements | Yes |
| Height | 130 mm |
| Hood version | Polycarbonate |
| Housing material | Metal |
| Input | 4 kV (Test Level 4 - asymmetrical) |
| Input | 3 kV (Test Level 3 - symmetrical) |
| Input | 6 kV (Test Level 4 - asymmetrical) |
| Input Current 2ac | 2 x 2.3-1.9 A |
| Input Current 3ac | 3 x 1.2-1.0 A |
| Input fuse | 3.15 A (internal (device protection), slow-blow) |
| Input Voltage 2ac | 2 x 400-500 V~ (-10% / +15%) |
| Input Voltage 3ac | 3 x 400-500 V~ (-20% / +15%) |
| Input voltage range | 2x 400 V AC ... 500 V AC -10 % ... +15 % |
| Input voltage range AC | 3x 320 V AC ... 575 V AC |
| Input/Output | asymmetrical |
| Inrush current integral (I 2 t) | ≤ 0.5 A 2 s |
| Installation distance right/left | 0 mm / 0 mm |
| Installation distance top/bottom | 50 mm / 50 mm |
| Insulation voltage input/output | 3 kV AC (type test) |
| Insulation voltage input/output | 1.5 kV AC (routine test) |
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| Mains buffering time | typ. 10 ms (400 V AC) |
| Mains buffering time | typ. 20 ms (500 V AC) |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Maximum altitude | ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m) |
| Maximum no-load power dissipation | < 1.2 W (400 V AC) |
| Minimum order quantity | 1 pc |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| Mounting type | DIN rail mounting |
| MTBF (IEC 61709, SN 29500) | > 1800000 h (25 °C) |
| MTBF (IEC 61709, SN 29500) | > 1100000 h (40 °C) |
| MTBF (IEC 61709, SN 29500) | > 510000 h (60 °C) |
| Network type | Star network |
| No-load proof | yes |
| Nominal input voltage range | 2x 400 V AC ... 500 V AC |
| Nominal output current (I N ) | 20 A |
| Nominal power consumption | 822.2 VA |
| Number of periods | 25 periods |
| Number of periods | 10 periods |
| Number of periods | 1 period |
| Number of phases | 3 |
| Output | 2 kV (Test Level 3 - asymmetrical) |
| Output | 1 kV (Test Level 2 - symmetrical) |
| Output | 2 kV (Test Level 1 - asymmetrical) |
| Output characteristic | U/I with dynamic load reserve |
| Output power | 480 W |
| Output power | 720 W (5 s) |
| output_voltage | 24 V= |
| Overvoltage category (EN 62368-1) | II (≤ 2000 m) |
| Packing unit | 1 pc |
| Product key | CMPO33 |
| Product type | Power supply |
| Protection against overvoltage at the output (OVP) | ≤ 30 V DC |
| Protection class | I (in closed control cabinet) |
| Protective circuit | Transient surge protection; Varistor |
| Radio interference voltage in acc. with EN 55011 | EN 55011 (EN 55022) Class B, area of application: Industry and residential |
| Rail applications | EN 50121-4 |
| Residual ripple | ≤ 50 mV PP |
| Rise time | ≤ 120 ms (U OUT (10 % ... 90 %)) |
| Scip | 77f69704-4d41-4759-b065-1fc3ee8e18d6 |
| Setting range of the output voltage (U Set ) | 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) |
| Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Short-circuit-proof | yes |
| Signal | 1 kV (Test Level 2 - asymmetrical) |
| Signal | 1 kV (Test Level 1 - asymmetrical) |
| Signalization designation | DC OK |
| SIL in accordance with IEC 61508 | 0 |
| Single conductor/terminal point, stranded, with ferrule, max. | 2.5 mm² |
| Single conductor/terminal point, stranded, with ferrule, max. | 6 mm² |
| Single conductor/terminal point, stranded, with ferrule, max. | 1.5 mm² |
| Single conductor/terminal point, stranded, with ferrule, min. | 0.2 mm² |
| Standard - Electrical safety | IEC 62368-1 (SELV) |
| Standard - Safe isolation | DIN VDE 0100-410 |
| Standard - Safety of transformers | EN 61558-2-16 (air clearances and creepage distances only) |
| Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
| Standards/regulations | EN 55016 |
| Standards/regulations | EN 61000-6-3 (Class B) |
| Standards/regulations | EN 55011 (EN 55022) |
| Standards/regulations | EN 61000-4-2 |
| Standards/regulations | EN 61000-4-3 |
| Standards/regulations | EN 61000-4-4 |
| Standards/regulations | EN 61000-4-5 |
| Standards/regulations | EN 61000-4-6 |
| Standards/regulations | EN 61000-4-11 |
| Standards/regulations | EN 61000-6-3 |
| Status display | LED |
| Stripping length | 10 mm |
| Stripping length | 15 mm |
| Stripping length | 8 mm |
| terminal blocks) | V0 |
| Test field strength | 10 V/m (Test Level 3) |
| Type of housing | Aluminum (AlMg3) |
| Types of signaling | LED |
| Types of signaling | Floating signal contact |
| Typical national grid voltage | 3x 480 V AC |
| Typical response time | < 1 s |
| UL approvals | UL Listed UL 508 |
| UL approvals | UL/C-UL Recognized UL 60950-1 |
| UNSPSC 21.0 | 39121000 |
| Voltage | 230 V AC |
| Voltage Adjustment | 24-28 V |
| Voltage dip | 70 % |
| Voltage dip | 40 % |
| Voltage dip | 0 % |
| Weight per piece (excluding packing) | 1,493.96 g |
| Weight per piece (including packing) | 1,706 g |
| Width | 65 mm |
| With protective coating | no |