Zum Inhalt springen

Phoenix Contact QUINT4-PS/24DC/24DC/20/PT DC/DC-Wandler

Phoenix Contact QUINT4-PS/24DC/24DC/20/PT DC/DC-Wandler

Angebot anfragen

Menge, Zustand und Zielort angeben.

Angebot anfragen

Beschreibung

Phoenix Contact QUINT4-PS/24DC/24DC/20/PT gehört als DC/DC-Wandler zur Reihe QUINT POWER. Es liefert nominal 24 V DC am Ausgang. Es wird auf einer DIN-Schiene montiert und hat die Schutzart IP20.

Spezifikationen

Brand Phoenix Contact
Model QUINT4-PS/24DC/24DC/20/PT
Order Number 2910121
HS Code 850440
Voltage 10 V (Test Level 3)
Frequency 16.7 Hz
Current 10 A
Inrush current typ. 2.7 A
Nominal output voltage 24 V DC
Power dissipation SLEEP MODE < 2 W
Power loss nominal load max. < 26.6 W
Switching frequency 190.00 kHz ... 220.00 kHz (Auxiliary converter stage)
Frequency range 80 MHz ... 1 GHz
Input voltage range 24 V DC -25 % ... +40 %
Nominal input voltage range 24 V DC -25 % ... +40 %
Degree of protection IP20
Recommended breaker for input protection 50 A (Characteristic B, C or comparable)
Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min, resonance frequency 2.3g, 90 min
EMC requirements for noise emission EN 61000-6-3
EMC requirements for noise emission EN 61000-6-4
EMC requirements for noise immunity EN 61000-6-1
EMC requirements for noise immunity EN 61000-6-2
EMC requirements, power plant IEC 61850-3
EMC requirements, power plant EN 61000-6-5
REACH candidate substance (CAS No.) Lead (CAS: 7439-92-1)
Additional text 24 V DC
Additional text Bridge and deck area
Additional text 60 s
Additional text 3 s
Additional text DC, 60 s
Additional text Test Level 2
Alternating component 15 % (U N )
Alternating component 14 % (U N )
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (start-up type tested) -40 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
AWG (recommended) 20 ... 6
AWG (recommended) 24 ... 10
AWG (recommended) 24 ... 16
Climatic class 3K22 (in accordance with EN 60721-3-3)
CO2e kg 30.597 kg CO2e
Comments Criterion A
Comments Criterion B
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Connection labeling 3.3 +
Connection labeling 3.5 +
Connection labeling 3.6 +
Connection labeling 3.1, 3.2
Connection labeling 3.4 +
Connection method Push-in connection
Contact discharge 8 kV (Test Level 4)
Control deviation dynamic < 3 % (change in load, static 10 % ... 90 %)
Control deviation Input voltage change < 3 % (change in load, static 10 % ... 90 %)
Control deviation static < 3 % (change in load, static 10 % ... 90 %)
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Current 20 A
Current consumption 27 A (24 V DC)
Default Output power ON (>40 kΩ/24 V DC/open bridge between REM and SGnd)
Default U IN input voltage OK
Default Output power
Default Output voltage
Degree of pollution 2
Depth 125 mm
Depth 73 mm
Digital 0 V DC
Digital 24 V DC
Digital 20 mA
Digital 1 A
Digital 30 V AC
Digital 0.5 A
Discharge in air 15 kV (Test Level 4)
Dnv Class B
Dynamic Boost (I Dyn.Boost ) 30 A (5 s)
ECLASS-13.0 27040701
ECLASS-15.0 27040701
Efficiency typ. 94.7 % (24 V DC)
Electric strength, max. 35 V DC (60 s)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Environment friendly use period (EFUP) EFUP-25 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
ETIM 10.0 EC002540
Exemption 6(c), 7(a), 7(c)-I
Feedback voltage resistance ≤ 35 V DC
Flexible 0.75 mm² ... 16 mm²
flexible 0.2 mm² ... 6 mm²
flexible 0.2 mm² ... 1.5 mm²
flexible with ferrule with plastic sleeve 0.75 mm² ... 16 mm²
flexible with ferrule with plastic sleeve 0.2 mm² ... 4 mm²
flexible with ferrule with plastic sleeve 0.2 mm² ... 0.75 mm²
flexible with ferrule without plastic sleeve 0.75 mm² ... 16 mm²
flexible with ferrule without plastic sleeve 0.2 mm² ... 4 mm²
flexible with ferrule without plastic sleeve 0.2 mm² ... 1.5 mm²
Frequency 50 Hz
Frequency 60 Hz
Frequency 0 Hz
Frequency 100 Hz
Frequency 150 Hz
Frequency 300 Hz
Frequency range 1 GHz ... 6 GHz
Frequency range 0.15 MHz ... 80 MHz
Frequency range 50 Hz ... 60 Hz
Fulfills EU RoHS substance requirements Yes
Function Output power ON/OFF (remote)
Function Signal ground
Fuse protection (secondary side) electronic
Fuse protection (secondary side) thermal-magnetic
Fuse protection (secondary side) thermal
Height 130 mm
Hood version Stainless steel X6Cr17
Housing material Metal
Identification UL Listed UL 61010-1
Identification UL Listed UL 61010-2-201
Identification UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
Identification CAN/CSA-C22.2 No. 61010-1-12
Identification CAN/CSA C22.2 No. 61010-2-201:18
Identification Type tested (type approved)
Identification CB scheme (IEC 61010-1, IEC 61010-2-201)
Identification DNV
Identification ABS
Identification BV
Identification NK
Identification LR
Input 2 kV (Test Level 3 - asymmetrical)
Input 1 kV (Test Level 3 - symmetrical)
Input, output (test level 1) 1 MHz (Test Level 2 - symmetrical)
Input, output (test level 2) 1 MHz (Test Level 2 - asymmetrical)
Input/output/signal asymmetrical
Inrush current integral (I 2 t) < 0.2 A 2 s
Inrush current limitation 2.7 A (after 1 ms)
Installation distance right/left (active) 15 mm / 15 mm
Installation distance right/left (passive) 5 mm / 5 mm
Installation distance top/bottom (active) 50 mm / 50 mm
Installation distance top/bottom (passive) 50 mm / 50 mm
Insulation voltage input/output 4 kV DC (type test)
Insulation voltage input/output 2 kV DC (routine test)
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Magnetic circuit breaker tripping A1...A16 / B2...B13 / C1...C6 / Z1...Z16
Mains buffering time typ. 16 ms (24 V DC)
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
Maximum no-load power dissipation < 4 W
Minimum order quantity 1 pc
Mounting type DIN rail mounting
MTBF (IEC 61709, SN 29500) > 1034000 h (25 °C)
MTBF (IEC 61709, SN 29500) > 577000 h (40 °C)
MTBF (IEC 61709, SN 29500) > 229000 h (60 °C)
No-load proof yes
Nominal output current (I N ) 20 A
Nominal power consumption 507 VA
Number of phases 1.00
Output 2 kV (Test Level 3 - asymmetrical)
Output 1 kV (Test Level 3 - symmetrical)
Output characteristic U/I Advanced
Output characteristic Smart HICCUP
Output characteristic FUSE MODE
Output power (P Dyn. Boost ) 720 W (5 s)
Output power (P N ) 480 W
Output power (P Stat. Boost ) 600 W
Overvoltage category (EN 61010-1) II (≤ 5000 m)
Overvoltage category (EN 62477-1) III (≤ 5000 m)
Packing unit 1 pc
Position 1.x
Position 2.x
Position 3.x
Product key CMDI43
Product type DC/DC converters
Protection against overvoltage at the output (OVP) ≤ 32 V DC
Protection class Special with SELV input and output
Reference potential to OUT1, OUT2, REM
Residual ripple < 50 mV PP
Rigid 1.5 mm² ... 16 mm²
rigid 0.2 mm² ... 6 mm²
rigid 0.2 mm² ... 1.5 mm²
Rise time < 100 ms (U OUT (10 % ... 90 %))
Scip 4bdb74f4-6fe2-4deb-8723-f3657ea880ee
Selective Fuse Breaking (I SFB ) 120 A (15 ms)
Setting range of the output voltage (U Set ) 24 V DC ... 29.5 V DC (> 24 V DC, constant capacity)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Short-circuit-proof yes
Side element version Aluminum
Signal 2 kV (Test Level 4 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Signal option Output voltage
Signal option Output current
Signal option Output power
Signal option Operating hours
Signal option Early warning of high temperatures
Signal option OVP voltage limitation active
Signal option U IN input voltage OK
Signal threshold > 100 % (LED lights up yellow, output power > 480 W)
Signal threshold > 75 % (LED lights up green, output power > 360 W)
Signal threshold > 50 % (LED lights up green, output power > 240 W)
Signal threshold > 0.9 x U Set (LED lights up green)
Signal threshold < 0.9 x U Set (LED flashes green)
Signal threshold > 0.8 x U InNom (LED off)
Signal threshold < 0.8 x U InNom (LED lights up yellow)
Signals (test level 1) 1 MHz (Test Level 2 - symmetrical)
Signals (test level 2) 1 MHz (Test Level 2 - asymmetrical)
Special properties The product is being prepared for compliance with the Cyber Resilience Act (CRA)
Standard designation Electrical safety (of control and regulation devices)
Standard designation Protective extra-low voltage
Standard designation Mains variation/undervoltage
Standard designation Railway applications
Standards/regulations EN 55016
Standards/regulations EN 61000-6-3 (Class B)
Standards/regulations Additional basic standard EN 61000-6-5 (immunity in switching devices), IEC/EN 61850-3 (power supply)
Standards/regulations EN 61000-4-2
Standards/regulations EN 61000-4-3
Standards/regulations EN 61000-4-4
Standards/regulations EN 61000-4-5
Standards/regulations EN 61000-4-6
Standards/regulations EN 61000-4-8
Standards/regulations EN 61000-4-29
Standards/regulations EN 61000-4-9
Standards/regulations EN 61000-4-16
Standards/regulations EN 61000-4-17
Standards/regulations EN 61000-4-18
Standards/regulations EN 61000-4-10
Standards/specifications IEC 61010-1
Standards/specifications EN 61010-1 (SELV)
Standards/specifications IEC 61010-2-201 (PELV)
Standards/specifications EN 61000-4-29
Standards/specifications EN 50121-3-2
Standards/specifications IEC 62236-3-2
Static Boost (I Stat.Boost ) 25 A
Stripping length 18 mm
Stripping length 10 mm
Stripping length 8 mm
Switch contact (floating) floating
Switch-on time < 1 s
Switching frequency 67.00 kHz ... 135.00 kHz (Main converter stage)
Temperature 40 °C
Temperature 30 °C
Temperature code T4 (-25 ... +70 °C; > 60 °C, Derating: 2,5 %/K)
terminal blocks) V0
Test field strength 20 V/m (Test Level 3)
Test field strength 10 V/m (Test Level 3)
Test field strength 100 A/m
Test field strength 1 kA/m
Test field strength 300 A/m
Test field strength 1000 A/m
Test level 1 15 Hz 150 Hz (Test Level 3)
Test level 1 100 kHz
Test level 2 150 Hz 1.5 kHz (Test Level 3)
Test level 2 1 MHz
Test level 3 1.5 kHz 15 kHz (Test Level 3)
Test level 4 15 kHz 150 kHz (Test Level 3)
Test level 5 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3)
Test level 6 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3)
Time 413707 h
Time 139340 h
Time 278680 h
Time 100 ms
Time 50 ms
Types of signaling LED
Types of signaling Floating signal contact
Types of signaling Active signal output Out1 (digital, configurable)
Types of signaling Active signal output Out2 (analog, configurable)
Types of signaling Remote contact
Types of signaling Signal ground SGnd
Typical response time 300 ms (from SLEEP MODE)
UNSPSC 21.0 39121000
Voltage 24 V DC
Voltage 10 V 1 V
Voltage 1 V
Voltage 1 V 10 V
Voltage 10 V
Voltage 10 V (Permanent)
Voltage 100 V (1 s)
Voltage 0.5 kV
Voltage 1 kV
Voltage dip 70 %
Voltage dip 40 %
Voltage dip 0 %
Weight per piece (excluding packing) 1,200 g
Weight per piece (including packing) 1,571 g
Wide-range input no
Width 70 mm
Width 122 mm
With protective coating no