Phoenix Contact QUINT4-PS/3AC/24DC/20 提供额定 24 V DC、20 A 输出,支持 DIN 导轨安装。官方参数还列出铁路应用标准 EN 50121-3-2、EN 50121-4 和 EN 50121-5。

规格参数

Brand Phoenix Contact
Model QUINT4-PS/3AC/24DC/20
Order Number 2904622
HS Code 850440
Voltage 10 V (Test Level 3)
Frequency 16.7 Hz
Current 10 A
Inrush current typ. 2 A (at 25 °C)
Nominal output voltage 24 V DC
Power dissipation SLEEP MODE < 5 W (400 V AC)
Power dissipation SLEEP MODE < 5 W (480 V AC)
Power factor 0.94
Power loss nominal load max. < 32 W (400 V AC)
Power loss nominal load max. < 33 W (480 V AC)
Standard – Safety extra-low voltage IEC 61010-1 (SELV)
Typical national grid voltage 400 V AC
Voltage type of supply voltage AC
Switching frequency 90.00 kHz ... 110.00 kHz (Auxiliary converter stage)
AC frequency range 50 Hz ... 60 Hz -10 % ... +10 %
Frequency range 0 kHz ... 2 kHz
Input voltage range 3x 400 V AC ... 500 V AC -20 % ... +10 %
Nominal input voltage range 3x 400 V AC ... 500 V AC
Degree of protection IP20
Recommended breaker for input protection 3x 4 A ... 20 A (Characteristic B, C or comparable)
Recommended fuse for input protection ≥ 300 V AC
Vibration (operation) 5 Hz ... 100 Hz resonance search 2.3g, 90 min., resonance frequency 2.3g, 90 min. (according to DNV GL Class C)
EMC requirements for noise emission EN 61000-6-3
EMC requirements for noise emission EN 61000-6-4
EMC requirements for noise immunity EN 61000-6-1
EMC requirements for noise immunity EN 61000-6-2
EMC requirements for power supply IEC 61850-3 (G,H)
EMC requirements for power supply EN 61000-6-5 (switching devices)
REACH candidate substance (CAS No.) Lead (CAS: 7439-92-1)
Shipbuilding approval DNV, PRS, BV, LR, ABS, NK
Additional text 400 V AC
Additional text 480 V AC
Additional text Area power distribution
Additional text Bridge and deck area
Additional text 60 s
Additional text 3 s
Additional text DC, 60 s
Additional text Test Level 2
Ambient temperature (operation) -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (start-up type tested) -40 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Analog 4 mA ... 20 mA ±5 % (Load ≤400 Ω)
Apparent power 686 VA (400 V, U OUT = 24 V, I OUT = stat. Boost)
Apparent power 698 VA (480 V, U OUT = 24 V, I OUT = stat. Boost)
Approval - requirement of the semiconductor industry with regard to mains voltage dips SEMI F47-0706, EN 61000-4-11
Battery charging DIN 41773-1
Climatic class 3K22 (in accordance with EN 60721-3-3)
CO2e kg 30.741 kg CO2e
Comments Criterion A
Comments Criterion A: 0.5 / 1 period Criterion B: 25 periods
Comments Criterion B
Comments Criterion A: 0.5 / 1 period Criterion B: 5 / 50 / 250 periods
Conductor cross-section AWG max. 10
Conductor cross-section AWG max. 16
Conductor cross-section AWG min. 24
Conductor cross-section flexible max. 4 mm²
Conductor cross-section flexible max. 1.5 mm²
Conductor cross-section flexible min. 0.2 mm²
Conductor cross-section, rigid max. 6 mm²
Conductor cross-section, rigid max. 1.5 mm²
Conductor cross-section, rigid min. 0.2 mm²
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Connection method Screw connection
Connection method Push-in connection
Contact discharge 8 kV (Test Level 4)
Control deviation < 0.5 % (Static load change 10 % ... 90 %)
Control deviation < 3 % (Dynamic load change 10 % ... 90 %, (10 Hz))
Control deviation < 0.25 % (change in input voltage ±10 %)
Control input (configurable) Rem Output power ON/OFF (SLEEP MODE)
Crest factor typ. 1.78 (400 V AC)
Crest factor typ. 2.1 (480 V AC)
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Csa CAN/CSA-C22.2 No. 60950-1-07
CSA CSA-C22.2 No. 107.1-01
Current 20 A
Current consumption 3x 0.99 A (400 V AC)
Current consumption 3x 0.81 A (480 V AC)
Current consumption 2x 1.62 A (400 V AC)
Current consumption 2x 1.37 A (480 V AC)
Current consumption 3x 0.8 A (500 V AC)
Current consumption 2x 1.23 A (500 V AC)
Current consumption 1.23 A (± 260 V DC)
Current consumption 1.06 A (±300 V DC)
Default Output power ON (>40 kΩ/24 V DC/open bridge between Rem and SGnd)
Default 24 V DC 20 mA 24 V DC for U Out > 0.9 x U Set
Default 24 V DC 20 mA 24 V DC for P Out < P N
Default closed (U out > 0.9 U Set )
Degree of pollution 2
Depth 125 mm
Depth 73 mm
Derating > 60 °C ... 70 °C (2.5 %/K)
Digital 24 V DC 20 mA
Digital 24 V DC 1 A
Digital 30 V AC/DC 0.5 A
Discharge current to PE < 3.5 mA
Discharge current to PE 1.7 mA (550 V AC, 60 Hz)
Discharge in air 15 kV (Test Level 4)
Dnv Class A
DNV Class B
Dynamic Boost (I Dyn.Boost ) 30 A (5 s)
ECLASS-13.0 27040701
ECLASS-15.0 27040701
Efficiency typ. 93.9 % (400 V AC)
Efficiency typ. 93.8 % (480 V AC)
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Environment friendly use period (EFUP) EFUP-25 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
Environmental protection directive RoHS Directive 2011/65/EU
Environmental protection directive WEEE
Environmental protection directive Reach
ETIM 10.0 EC002540
Exemption 7(a), 7(c)-I
Feedback voltage resistance ≤ 35 V DC
Frequency 50 Hz
Frequency 60 Hz
Frequency 0 Hz
Frequency range 80 MHz ... 1 GHz
Frequency range 1 GHz ... 6 GHz
Frequency range 0.15 MHz ... 80 MHz
Frequency range 50 Hz ... 60 Hz
Frequency range (f N ) 50 Hz ... 60 Hz -10 % ... +10 %
Fulfills EU RoHS substance requirements Yes
Fuse protection (secondary side) electronic
Fuse protection (secondary side) thermal-magnetic
Fuse protection (secondary side) thermal
HART FSK Physical Layer Test Specification Compliance Output voltage U Out compliant
Height 130 mm
Hood version Stainless steel X6Cr17
Housing material Metal
Input 4 kV (Test Level 4 - asymmetrical)
Input 2 kV (Test Level 4 - symmetrical)
Input 6 kV (Test Level 4 - asymmetrical)
Input voltage range 2x 400 V AC ... 500 V AC -10 % ... +10 %
Input voltage range ± 260 V DC ... 300 V DC -13 % ... +30 %
Input voltage range 520 V DC ... 600 V DC -13 % ... +30 % (mid-point earthed)
Input, output (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
Input, output (test level 2) 10 MHz
Input, output (test level 3) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
Input/output/signal asymmetrical
Inrush current integral (I 2 t) < 0.1 A 2 s
Inrush current limitation 2 A (after 1 ms)
Installation distance right/left 5 mm / 5 mm
Installation distance top/bottom 50 mm / 50 mm
Insulation voltage input/output 4 kV AC (type test)
Insulation voltage input/output 2.4 kV AC (routine test)
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Magnetic circuit breaker tripping A1...A16 / B2...B13 / C1...C6 / Z1...Z16
Mains buffering time typ. 33 ms (3x 400 V AC)
Mains buffering time typ. 33 ms (3x 480 V AC)
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Maximum altitude ≤ 5000 m (> 2000 m, observe derating)
Maximum no-load power dissipation < 7 W (400 V AC)
Maximum no-load power dissipation < 7 W (480 V AC)
Minimum order quantity 1 pc
Mounting position horizontal DIN rail NS 35, EN 60715
Mounting type DIN rail mounting
MTBF (IEC 61709, SN 29500) > 985000 h (25 °C)
MTBF (IEC 61709, SN 29500) > 638000 h (40 °C)
MTBF (IEC 61709, SN 29500) > 311000 h (60 °C)
Network type Star network
No-load proof yes
Nominal input voltage range 2x 400 V AC ... 500 V AC
Nominal input voltage range ± 260 V DC ... 300 V DC
Nominal output current (I N ) 20 A
Nominal power consumption 541 VA
Number of periods 0.5 / 1 / 25 periods
Number of periods 5 / 10 / 50 periods
Number of periods 0,5 / 1 / 5 / 50 / 250 periods
Number of phases 3
Output 4 kV (Test Level 4 - asymmetrical)
Output 1 kV (Test Level 3 - symmetrical)
Output 2 kV (Test Level 3 - asymmetrical)
Output characteristic U/I Advanced
Output characteristic Smart HICCUP
Output characteristic FUSE MODE
Output power 480 W
Output power 600 W
Output power 720 W
Overvoltage category (EN 61010-1) II (≤ 5000 m)
Overvoltage category (EN 61558-2-16) II (≤ 5000 m)
Overvoltage category (EN 62477-1) III (≤ 2000 m)
P Out > 100 % (LED lights up yellow, output power > 480 W)
P Out > 75 % (LED lights up green, output power > 360 W)
P Out > 50 % (LED lights up green, output power > 240 W)
Packing unit 1 pc
PE 3.5 kV AC (type test)
PE 0.5 kV DC (type test)
PE 2.4 kV AC (routine test)
PE 0.5 kV DC (routine test)
Product key CMPI33
Product type Power supply
Protection against overvoltage at the output (OVP) ≤ 32 V DC
Protection class I
Protective circuit Transient surge protection; Varistor, gas-filled surge arrester
Rail applications EN 50121-3-2
Rail applications EN 50121-4
Rail applications EN 50121-5
Rail applications IEC 62236-3-2
Rail applications IEC 62236-4
Rail applications IEC 62236-5
Recommended breaker for input protection 1x 6 A (10 x 38 mm, 30 kA L/R = 2 ms)
Recommended fuse for input protection ≥ 1000 V DC
Residual ripple < 60 mV PP (with nominal values)
Rise time < 80 ms (U Out = 10 % ... 90 %)
Scip 6d1e5389-7e7a-4cce-8aa5-31f8463446ae
Selective Fuse Breaking (I SFB ) 120 A (15 ms)
Setting range of the output voltage (U Set ) 24 V DC ... 29.5 V DC (constant capacity)
Shock 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Short-circuit-proof yes
Side element version Aluminum
Signal 2 kV (Test Level 4 - asymmetrical)
Signal 1 kV (Test Level 2 - asymmetrical)
Signal ground SGnd Reference potential for Out1, Out2, and Rem
Signal option Output current
Signal option Output voltage
Signal option Output power
Signal option U IN input voltage OK
Signal option Operating hours
Signal option Early warning of high temperatures
Signal option OVP voltage limitation active
Signal option Phase monitoring
Signals (test level 1) 100 kHz 1 MHz (Test Level 3 - symmetrical)
Signals (test level 2) 100 kHz 1 MHz (Test Level 3 - asymmetrical)
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 4 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max. 0.75 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min. 0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 4 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max. 1.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.25 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min. 0.2 mm²
Siq BG (type approved)
SIQ CB-Scheme (IEC 61010-1, IEC 61010-2-201, IEC 60950-1)
Standard - Electrical safety IEC 61010-2-201 (SELV)
Standard - power supply devices for low voltage with DC output EN 61204-3
Standard - Safe isolation IEC 61558-2-16
Standard - Safe isolation IEC 61010-2-201
Standard - safety for equipment for measurement, control, and laboratory use IEC 61010-1
Standard - Safety of transformers EN 61558-2-16
Standard – Limitation of mains harmonic currents EN 61000-3-2
Standard – Safety extra-low voltage IEC 61010-2-201 (PELV)
Standards/regulations EN 55016
Standards/regulations EN 61000-6-3 (Class B)
Standards/regulations Additional basic standard EN 61000-6-5 (immunity in switching devices), IEC/EN 61850-3 (power supply)
Standards/regulations EN 61000-3-2
Standards/regulations EN 61000-3-2 (Class A)
Standards/regulations EN 61000-3-3
Standards/regulations EN 61000-4-2
Standards/regulations EN 61000-4-3
Standards/regulations EN 61000-4-4
Standards/regulations EN 61000-4-5
Standards/regulations EN 61000-4-6
Standards/regulations EN 61000-4-8
Standards/regulations EN 61000-4-11
Standards/regulations EN 61000-4-9
Standards/regulations EN 61000-4-12
Standards/regulations EN 61000-4-16
Standards/regulations EN 61000-4-18
Standards/regulations EN 61000-4-10
Static Boost (I Stat.Boost ) 25 A
Stripping length 8 mm
Switch-on time < 1 s
Switching frequency 56.00 kHz ... 500.00 kHz (Main converter stage)
Switching frequency 25.00 kHz ... 500.00 kHz (PFC stage)
Temperature 40 °C
Temperature 25 °C
Temperature code T4 (-25 ... +70 °C; > 60 °C, Derating: 2,5 %/K)
terminal blocks) V0
Test field strength 20 V/m (Test Level 3)
Test field strength 10 V/m (Test Level 3)
Test field strength 100 A/m
Test field strength 1 kA/m
Test field strength 300 A/m
Test field strength 1000 A/m
Test level 1 15 Hz 150 Hz (Test Level 4)
Test level 1 100 kHz
Test level 2 150 Hz 1.5 kHz (Test Level 4)
Test level 2 1 MHz
Test level 3 1.5 kHz 15 kHz (Test Level 4)
Test level 4 15 kHz 150 kHz (Test Level 4)
Test level 5 16.7 Hz 50 Hz 60 Hz (Test Level 4)
Test level 6 16.7 Hz 50 Hz 60 Hz (Test Level 4)
Tightening torque max 0.6 Nm
Tightening torque, min 0.5 Nm
Time 344000 h
Time 320000 h
Time 445000 h
Time 432000 h
Time 157000 h
Time 152000 h
Types of signaling LED
Types of signaling Floating signal contact
Types of signaling Active signal output Out1 (digital, configurable)
Types of signaling Active signal output Out2 (analog, configurable)
Types of signaling Remote contact
Types of signaling Signal ground SGnd
Typical national grid voltage 480 V AC
Typical response time 300 ms (from SLEEP MODE)
U Out > 0.9 x U Set (LED lights up green)
U Out < 0.9 x U Set (LED flashes green)
UL approvals UL Listed UL 508
UL approvals UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location)
UL approvals UL/C-UL Recognized UL 60950-1
UNSPSC 21.0 39121000
Voltage 400 V AC
Voltage 30 V 3 V
Voltage 3 V
Voltage 3 V 30 V
Voltage 30 V
Voltage 30 V (Permanent)
Voltage 300 V (1 s)
Voltage 1 kV
Voltage 2.5 kV
Voltage dip 70 %
Voltage dip 40 %
Voltage dip 0 %
Voltage type of supply voltage DC
Weight per piece (excluding packing) 1,203 g
Weight per piece (including packing) 1,562 g
Width 70 mm
Width 122 mm
With protective coating no