Procurar categorias
Conversor DC/DC Phoenix Contact QUINT4-PS/12-24DC/24DC/1.3/SC 1066703 - Novo
Descricao
Conversor DC/DC Phoenix Contact QUINT4-PS/12-24DC/24DC/1.3/SC novo, número de peça 1066703. Tensão de entrada DC 12-24 V, corrente de saída 1,3 A.
Especificacoes
| Brand | Phoenix Contact |
|---|---|
| Model | QUINT4-PS/12-24DC/24DC/1.3/SC |
| Order Number | 1066703 |
| HS Code | 850440 |
| Voltage | 10 V (Test Level 3) |
| Frequency | 16.67 Hz |
| Current | 0.65 A |
| Input Voltage | DC 12-24 V |
| Output Current | 1.3 A |
| Inrush current | typ. 1.6 A |
| Nominal output voltage | 24 V DC |
| Power loss nominal load max. | < 8 W |
| Switching frequency | 130.00 kHz ... 130.00 kHz (Auxiliary converter stage) |
| Frequency range | 80 MHz ... 1 GHz |
| Input voltage range | 12 V DC ... 24 V DC -25 % ... +33 % (SELV) |
| Nominal input voltage range | 12 V DC ... 24 V DC |
| Degree of protection | IP20 |
| Recommended breaker for input protection | 10 A ... 16 A (Characteristic B, C, D, K or comparable) |
| Vibration (operation) | < 15 Hz, ±2.5 mm amplitude; 15 Hz ... 100 Hz: 2.3 g 90 Min. (in accordance with IEC 60068-2-6) |
| EMC requirements for noise emission | EN 61000-6-3 |
| EMC requirements for noise emission | EN 61000-6-4 |
| EMC requirements for noise immunity | EN 61000-6-1 |
| EMC requirements for noise immunity | EN 61000-6-2 |
| EMC requirements, power plant | EN 61850-3 |
| EMC requirements, power plant | EN 61000-6-5 |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
| Additional text | 24 V DC |
| Additional text | Bridge and deck area |
| Additional text | 60 s |
| Additional text | 3 s |
| Additional text | DC, 60 s |
| Additional text | Test Level 2 |
| Alternating component | 10 % (U N ) |
| Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K) |
| Ambient temperature (start-up type tested) | -40 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Climatic class | 3K3 (in acc. with EN 60721) |
| CO2e kg | 8.478 kg CO2e |
| Comments | Criterion A |
| Comments | Criterion B |
| Connection in parallel | yes, for redundancy and increased capacity |
| Connection in series | yes |
| Connection method | Screw connection |
| Contact discharge | 6 kV (Test Level 4) |
| Control deviation dynamic | < 1 % (change in load, static 10 % ... 90 %) |
| Control deviation Input voltage change | < 1 % (change in load, static 10 % ... 90 %) |
| Control deviation static | < 1 % (change in load, static 10 % ... 90 %) |
| Criterion A | Normal operating behavior within the specified limits. |
| Criterion B | Temporary impairment to operational behavior that is corrected by the device itself. |
| Criterion C | Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements. |
| Current | 1.3 A |
| Current consumption | typ. 3.75 A (12 V DC) |
| Current consumption | typ. 1.85 A (24 V DC) |
| Default | 24 V DC |
| Default | 22 mA |
| Default | 24 V DC for U Out > 0.9 x U Set |
| Degree of pollution | 2 |
| Depth | 90 mm |
| Derating | > 60 °C (2.5%/K of P Out nom.) |
| Digital | 0 V DC |
| Digital | 24 V DC |
| Digital | 22 mA |
| Discharge in air | 8 kV (Test Level 3) |
| Dnv | Class B |
| Drive form screw head | Slotted L |
| Dynamic Boost (I Dyn.Boost ) | 2.6 A (≤ 60 °C (4.9 s)) |
| ECLASS-13.0 | 27040701 |
| ECLASS-15.0 | 27040701 |
| Efficiency | typ. 91.7 % (24 V DC) |
| Electric strength, max. | 35 V DC (60 s) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Environment friendly use period (EFUP) | EFUP-25 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. |
| ETIM 10.0 | EC002540 |
| Exemption | 6(c), 7(a), 7(c)-I |
| Feedback voltage resistance | ≤ 35 V DC |
| Flexible | 0.5 mm² ... 2.5 mm² |
| flexible | 0.25 mm² ... 2.5 mm² |
| flexible | 0.14 mm² ... 2.5 mm² |
| flexible with ferrule with plastic sleeve | 0.5 mm² ... 2.5 mm² |
| flexible with ferrule with plastic sleeve | 0.25 mm² ... 2.5 mm² |
| flexible with ferrule without plastic sleeve | 0.5 mm² ... 2.5 mm² |
| flexible with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Frequency | 50 Hz |
| Frequency | 60 Hz |
| Frequency | 0 Hz |
| Frequency | 100 Hz |
| Frequency | 150 Hz |
| Frequency | 300 Hz |
| Frequency range | 1 GHz ... 6 GHz |
| Frequency range | 0.15 MHz ... 80 MHz |
| Frequency range | 50 Hz ... 60 Hz |
| Fulfills EU RoHS substance requirements | Yes |
| Fuse protection (secondary side) | electronic |
| Height | 99 mm |
| Housing material | Plastic |
| Identification | UL Listed UL 61010-1 |
| Identification | UL Listed UL 61010-2-201 |
| Identification | UL 121201 & CSA C22.2 No. 213-17 Class I, Division 2, Groups A, B, C, D T4 (Hazardous Location) |
| Identification | CAN/CSA C22.2 No. 61010-1-12 |
| Identification | CAN/CSA C22.2 No. 61010-2-201:18 |
| Identification | CB scheme (IEC 61010-1, IEC 61010-2-201) |
| Identification | DNV GL |
| Input | 2 kV (Test Level 4 - asymmetrical) |
| Input | 1 kV (Test Level 4 - symmetrical) |
| Input fuse | 15 A (fast blow, internal) |
| Input, output (test level 1) | 1 MHz (Test Level 2 - symmetrical) |
| Input, output (test level 2) | 1 MHz (Test Level 2 - asymmetrical) |
| Input/output/signal | asymmetrical |
| Inrush current integral (I 2 t) | typ. 0.1 A 2 s |
| Inrush current limitation | typ. 1.6 A |
| Installation distance right/left (active) | 15 mm / 15 mm (P Out ≥50% ) |
| Installation distance right/left (active, passive) | 0 mm / 0 mm (P Out ≤50 %) |
| Installation distance right/left (passive) | 5 mm / 5 mm (P Out ≥50% ) |
| Installation distance top/bottom (active) | 30 mm / 30 mm (P Out ≥50% ) |
| Installation distance top/bottom (active, passive) | 30 mm / 30 mm (P Out ≤50 %) |
| Installation distance top/bottom (passive) | 30 mm / 30 mm (P Out ≥50% ) |
| Insulation voltage input/output | 2.6 kV DC (type test) |
| Insulation voltage input/output | 1.2 kV DC (routine test) |
| Mains buffering time | typ. 19 ms (24 V DC) |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Maximum altitude | ≤ 5000 m (> 2000 m, observe derating) |
| Maximum no-load power dissipation | < 1.3 W |
| Minimum order quantity | 1 pc |
| Mounting type | DIN rail mounting |
| MTBF (IEC 61709, SN 29500) | > 1999348 h (25 °C) |
| MTBF (IEC 61709, SN 29500) | > 1120490 h (40 °C) |
| MTBF (IEC 61709, SN 29500) | > 471066 h (60 °C) |
| No-load proof | yes |
| Nominal output current (I N ) | 1.3 A |
| Number of periods | 0.5 / 1 / 25 periods |
| Number of periods | 5 / 10 / 50 periods |
| Number of periods | 0.5 / 1 / 5 / 50 periods |
| Number of phases | 1.00 |
| Output | 2 kV (Test Level 4 - asymmetrical) |
| Output | 1 kV (Test Level 3 - symmetrical) |
| Output | 2 kV (Test Level 3 - asymmetrical) |
| Output characteristic | U/I Advanced |
| Output power (P Dyn. Boost ) | 60 W |
| Output power (P N ) | 30 W |
| Output power (P Stat. Boost ) | 38 W |
| Overvoltage category (EN 61010-1) | II (≤ 5000 m) |
| Packing unit | 1 pc |
| Position | 1.x |
| Position | 2.x |
| Position | 3.x |
| Product key | CMDI43 |
| Product type | DC/DC converters |
| Protection against overvoltage at the output (OVP) | < 32 V DC |
| Protection class | II |
| Residual ripple | < 20 mV PP |
| Rigid | 0.5 mm² ... 2.5 mm² |
| rigid | 0.2 mm² ... 2.5 mm² |
| rigid | 0.14 mm² ... 2.5 mm² |
| rigid (AWG) | 22 ... 14 |
| rigid (AWG) | 24 ... 14 |
| rigid (AWG) | 26 ... 14 |
| Rise time | < 1 s (U OUT (10 % ... 90 %)) |
| Scip | c5e7fff1-8bf2-42c7-a0f9-d9d005d0147f |
| Setting range of the output voltage (U Set ) | 24 V DC ... 28 V DC (> 24 V DC, constant capacity) |
| Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Short-circuit-proof | yes |
| Signal | 2 kV (Test Level 4 - asymmetrical) |
| Signal | 1 kV (Test Level 4 - symmetrical) |
| Signal threshold | > P Thr (LED lights up yellow, output power > P Thr, depending on the rotary selector switch setting) |
| Signal threshold | > 0.9 x U Set (LED lights up green) |
| Signal threshold | < 0.9 x U Set (LED flashes green) |
| Signals (test level 1) | 1 MHz (Test Level 2 - symmetrical) |
| Signals (test level 2) | 1 MHz (Test Level 2 - asymmetrical) |
| Standard designation | Electrical safety (of control and regulation devices) |
| Standard designation | Protective extra-low voltage |
| Standard designation | Mains variation/undervoltage |
| Standards/regulations | EN 55016 |
| Standards/regulations | EN 61000-6-3 (Class B) |
| Standards/regulations | Additional basic standard EN 61000-6-5 (immunity in switching devices), IEC/EN 61850-3 (power supply) |
| Standards/regulations | EN 61000-4-2 |
| Standards/regulations | EN 61000-4-3 |
| Standards/regulations | EN 61000-4-4 |
| Standards/regulations | EN 61000-4-5 |
| Standards/regulations | EN 61000-4-6 |
| Standards/regulations | EN 61000-4-8 |
| Standards/regulations | EN 61000-4-29 |
| Standards/regulations | EN 61000-4-9 |
| Standards/regulations | EN 61000-4-16 |
| Standards/regulations | EN 61000-4-17 |
| Standards/regulations | EN 61000-4-18 |
| Standards/regulations | EN 61000-4-10 |
| Standards/specifications | IEC 61010-1 |
| Standards/specifications | IEC 61010-1 (SELV) |
| Standards/specifications | EN 61000-4-29 |
| Static Boost (I Stat.Boost ) | 1.625 A (≤ 40 °C) |
| Stripping length | 8 mm |
| Switch-on time | < 1 s |
| Switching frequency | 70.00 kHz ... 250.00 kHz (Main converter stage) |
| Temperature | 40 °C |
| Temperature | 30 °C |
| Temperature code | T4 (-25 ... +70 °C; > 60 °C, Derating: 2,5 %/K) |
| terminal blocks) | V0 |
| Test field strength | 20 V/m (Test Level 3) |
| Test field strength | 10 V/m (Test Level 3) |
| Test field strength | 100 A/m |
| Test field strength | 1 kA/m |
| Test field strength | 300 A/m |
| Test field strength | 1000 A/m |
| Test level 1 | 15 Hz 150 Hz (Test Level 3) |
| Test level 1 | 100 kHz |
| Test level 2 | 150 Hz 1.5 kHz (Test Level 3) |
| Test level 2 | 1 MHz |
| Test level 3 | 1.5 kHz 15 kHz (Test Level 3) |
| Test level 4 | 15 kHz 150 kHz (Test Level 3) |
| Test level 5 | 16.7 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3) |
| Test level 6 | 0 Hz 16.7 Hz 50 Hz 60 Hz (Test Level 3) |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Time | 242000 h |
| Time | 160000 h |
| Time | 320000 h |
| Time | 100 ms |
| Time | 50 ms |
| Type of housing | Polycarbonate (PC), UL 94 V0 |
| Typical response time | 700 ms (from SLEEP MODE) |
| UNSPSC 21.0 | 39121000 |
| Voltage | 24 V DC |
| Voltage | 10 V 1 V (Permanent) |
| Voltage | 1 V |
| Voltage | 1 V 10 V |
| Voltage | 10 V |
| Voltage | 10 V (Permanent) |
| Voltage | 100 V (1 s) |
| Voltage | 0.5 kV |
| Voltage | 1 kV |
| Voltage dip | 70 % |
| Voltage dip | 40 % |
| Voltage dip | 0 % |
| Weight per piece (excluding packing) | 169 g |
| Weight per piece (including packing) | 227.6 g |
| Wide-range input | yes |
| Width | 22.5 mm |
| With protective coating | no |