Procurar categorias
Phoenix Contact FL SWITCH 2504-2GC-2SFP switch Ethernet industrial
Descricao
Phoenix Contact FL SWITCH 2504-2GC-2SFP integra a linha Managed Switch 2000 como switch Ethernet industrial. O produto é montado em trilho DIN e tem grau de proteção IP20.
Especificacoes
| Brand | Phoenix Contact |
|---|---|
| Model | FL SWITCH 2504-2GC-2SFP |
| Order Number | 1088872 |
| HS Code | 851762 |
| Power supply connection | Via COMBICON, max. conductor cross-section 2.5 mm² |
| Supply voltage range | 19.2 V DC ... 32 V DC |
| Signal contact control voltage | typ. 24 V DC |
| Transmission speed | 10/100/1000 Mbps |
| Vibration | A |
| Degree of protection | IP20 |
| Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
| Additional functions | Jumbo frames (max. 9,600 bytes) |
| Additional functions | Transmission of MMS and GOOSE (IEC 61850-8-1) |
| Additional functions | Transmission of Modbus/TCP |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Basic functions | Store-and-forward switch, complies with IEEE 802.3 |
| Color (Housing) | Steel/stainless steel color |
| Conductor cross-section AWG | 24 ... 16 |
| Conductor cross-section, flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross-section, rigid | 0.2 mm² ... 1.5 mm² |
| Conformance with EMC directives | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B |
| Conformance with EMC directives | EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A |
| Conformance with EMC directives | EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A |
| Conformance with EMC directives | EN 61000-6-2 EN 61000-4-5 (surge) Criterion A |
| Conformance with EMC directives | EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A |
| Conformance with EMC directives | EN 61000-6-2 EN 61000-6-4 (interference) Class A |
| Conformance with EMC directives | EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A |
| Connection method | RJ45 |
| Connection method | SFP |
| Connection method | SFP/RJ45 |
| Connection method | Push-in spring connection |
| Degree of pollution | 2 |
| Depth | 67 mm |
| Diagnostic functions | RMON History |
| Diagnostic functions | LLDP (Link Layer Discovery Protocol) |
| Diagnostic functions | SNMP-Traps |
| Diagnostic functions | N:1-Portmirroring |
| Diagnostic functions | ACD (Address Conflict Detection) |
| Diagnostic functions | SysLog |
| Diagnostic functions | CRC-Surveillance |
| ECLASS-13.0 | 19170401 |
| ECLASS-15.0 | 19170401 |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Emc | B |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Environment friendly use period (EFUP) | EFUP-50 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. |
| ETIM 10.0 | EC000734 |
| Exemption | 7(a), 7(c)-I |
| Filter functions | Quality of Service (8 priority classes) |
| Filter functions | Class of Service |
| Filter functions | DiffServ/DSCP |
| Filter functions | Port-Priorisierung |
| Filter functions | IGMP Snooping/Querier (v1/v2) |
| Filter functions | Auto-Query-Port |
| Filter functions | Extended Multicast Filtering |
| Free from substances that could impair the application of coating | Yes |
| Fulfills EU RoHS substance requirements | Yes |
| Height | 113 mm |
| Housing material | Stainless steel 1.4301 |
| Humidity | B |
| Identification | cULus |
| Identification | ISA S71.04.2013 G3 Harsh Group A |
| IP parameterization | DHCP client |
| IP parameterization | DHCP server (pool-based, port-based) |
| IP parameterization | BootP |
| IP parameterization | DCP (Discovery and Configuration Protocol) |
| Local diagnostics | US1/2 Supply voltage US1, US2 Green LED |
| Local diagnostics | FAIL Div. LED red |
| Local diagnostics | LNK/ACT Link status Green/orange LED |
| Local diagnostics | SPD Data transmission speed Green/orange LED |
| MAC address table | 8k |
| Management | Web-based management (HTTP/HTTPS) |
| Management | Role-based user management (LDAP, RADIUS) |
| Management | SNMPv1/v2/v3 |
| Management | Command Line Interface (Telnet, SSH) |
| Material base plate | Die-cast aluminum, corrosion-resistant |
| Max. current consumption | 390 mA (U S = min, T amb = max) |
| Maximum power dissipation for nominal condition | 7.2 W (U S = max, T amb = max) |
| Minimum order quantity | 1 pc |
| Mounting type | DIN rail mounting |
| Mttf | 357.82 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| MTTF | 191.24 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
| MTTF | 25.65 Years (SN 29500 standard, temperature 70°C, operating cycle 100%) |
| No. of channels | 4 (RJ45 ports) |
| No. of channels | 2 (SFP ports) |
| No. of channels | 2 (Combo ports) |
| Noise immunity | EN 61000-6-2 |
| Number of interfaces | 2 |
| Packing unit | 1 pc |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
| Pluggable | yes |
| Port security | MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass |
| Product key | DNN122 |
| Product type | Switch |
| PROFINET conformance class | Conformance Class B |
| PROFINET device function | PROFINET device |
| PROFINET device function | Fast Startup |
| Protection class | III (VDE 0106) |
| Redundancy | MRP (Media Redundancy Protocol) |
| Redundancy | RSTP (Rapid Spanning Tree Protocol) |
| Redundancy | FRD (Fast Ring Detection) |
| Redundancy | Large Tree Support |
| Redundancy | LACP (Link Aggregation Control Protocol) |
| Redundancy | PROFINET S2 system redundancy |
| Residual ripple | 3.6 V PP (within the permitted voltage range) |
| Shock (operation) | 30g (EN 60068-2-27) |
| Signal delay | ≥ 1.9 µs (Store-and-Forward mode, 10/100/1000 Mbps, depending on the frame size) |
| Signal LEDs | Data receive, link status |
| Special properties | Extended temperature range |
| Special properties | Development process certified in accordance with IEC 62443-4-1 |
| Special properties | Product certified in accordance with IEC 62443-4-2 |
| Special properties | The product is being prepared for compliance with the Cyber Resilience Act (CRA) |
| Standards/regulations | EN 61000-6-4 |
| Status and diagnostic indicators | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed) |
| Status display | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed) |
| Stripping length | 10 mm |
| Supply voltage (DC) | 24 V DC (redundant) |
| Temperature | B |
| Test section | 24 V supply / functional ground 500 V DC 1 min |
| Test section | Ethernet interface/all other potentials 2.25 kV DC 1 min |
| Time synchronization | SNTP (Simple Network Time Protocol) |
| Transmission length | 100 m (per segment) |
| Transmission medium | Copper |
| Transmission medium | FO |
| Transmission physics | Copper |
| Transmission physics | Depending on the SFP module |
| Transmission speed | 100/1000 Mbps (full duplex) |
| Transmission speed | 10/100/1000 Mbps (full duplex) |
| Type | Block design |
| Typical current consumption | 270 mA (at U S = 24 V DC and 25 °C ambient temperature) |
| UNSPSC 21.0 | 43222600 |
| Weight per piece (excluding packing) | 650 g |
| Weight per piece (including packing) | 796 g |
| Width | 128 mm |