Procurar categorias
B&R ACOPOSmulti 8B0C0160HW00.000-1 acionamento de servo - Usado
Solicitar cotacao
Diga-nos o que voce precisa e entraremos em contato sobre disponibilidade e preco.
Iniciar solicitacaoDescricao
Acionamento de servo B&R ACOPOSmulti 8B0C0160HW00.000-1, usado, removido de equipamento. Fabricado na Áustria.
Especificacoes
| Brand | B&R |
|---|---|
| Model | ACOPOSmulti |
| MPN | 8B0C0160HW00.000-1 |
| Origin | Austria |
| Nominal | 750 VDC |
| Variant | ACOPOSmulti backplane |
| Width | 53 mm |
| Height | 317 mm |
| Weight | Approx. 3 kg |
| Maximum | 55°C |
| Nominal | 5 to 40°C |
| Storage | -25 to 55°C |
| CE | Yes |
| KC | Yes |
| UL | cULus E225616 Power conversion equipment |
| Transport | -25 to 70°C |
| UKCA | Yes |
| Module width | 1 |
| Wall mounting | 263 mm |
| Storage | 5 to 95% |
| DC bus capacitance | 220 nF |
| Operation | 5 to 85% |
| Transport | Max. 95% at 40°C |
| Full continuous power | 315 to 800 VDC |
| Continuous power consumption | Max. 445 W |
| CRA (Cyber Resilience Act) | In preparation |
| Cooling and mounting type | Wall mounting |
| Variant | ACOPOSmulti backplane |
| DC bus voltage (U DC ) | 25 VDC * (U DC / 315) |
| DC bus voltage (U DC ) | 24 VDC ±6% |
| Operating range in continuous operation | 260 to 800 VDC |
| Power dissipation with continuous power | 22 W (0% continuous power) 27 W (50% continuous power) 45 W (100% continuous power) |
| Maximum | 4000 m |
| Nominal | 0 to 500 m |
| No-load proof | Yes |
| Output voltage | 25 VDC ±1.6% |
| Overload-proof | Yes |
| Hanging vertically | Yes |
| Horizontal, face up | Yes |
| Feedback protection | Max. 26 VDC (also when the power is switched off) |
| Short-circuit proof | Yes |
| Standing horizontally | No |
| Output/Input isolation | SELV / PELV requirements |
| Overtemperature protection | Yes |
| Dielectric strength to ground | ±50 VDC |
| 24 VDC internal system power supply | 21 ADC |
| Startup time | Approx. 5 to 20 ms |
| Startup delay | Max. 1 s |
| Installation elevation above sea level | IP20 |
| Installation elevation above sea level | 2 (non-conductive pollution) |
| Residual ripple | Typ. 50 mV SS |
| Continuous power | 400 W |
| Installation elevation above sea level | III |
| Continuous current | 16 ADC |
| Reduction of continuous power depending on installation elevation | No reduction |
| Reduction of continuous power depending on installation elevation | 40 W per 1000 m |
| Reduction of continuous power depending on cooling method | No reduction |