Skip to content

WAGO 750-657 IO-Link Master

WAGO 750-657 IO-Link Master

Request a Quote

Quantity, condition and destination.

Request quote

Description

The WAGO 750-657 IO-Link Master mounts on DIN-35 rail and permits a cable length of up to 20 m.

Specifications

Brand WAGO
MPN 750-657
Connection type Inputs/Outputs
Weight 49.6 g
Vibration resistance Per IEC 60068-2-6
CAS-No. 1303-86-2; 1317-36-8; 7439-92-1; 79-94-7
EMC emission of interference per EN 61000-6-4, EN 61131-2
EMC immunity to interference per EN 61000-6-2, EN 61131-2
REACH Candidate List Substance 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol; Diboron trioxide; Lead; Lead monoxide
Actuator connection 4 x (3-wire)
Ambient temperature (operation) 0 … +55 °C
Ambient temperature (storage) -40 … +85 °C
Conformity marking CE
Connectable conductor materials Copper
Connection requirement (permissible cable length) 20 m
Connection technology 16 x Push-in CAGE CLAMP®
Current consumption (system supply) 40 mA
Current consumption, field supply (module with no external load) 50 mA
Data width 4–24 bytes, configurable
Depth 69 mm / 2.717 inches
Depth from upper-edge of DIN-rail 61.8 mm / 2.433 inches
Eccn NO US CLASSIFICATION
eCl@ss 10.0 27-24-26-05
eCl@ss 9.0 27-24-26-05
End of Production 2023-12-31
End of Sale 2023-06-30
End of Service and Repair 2026-03-01
ETIM 9.0 EC001601
Exposure to pollutants Per IEC 60068-2-42 and IEC 60068-2-43
Fine-stranded conductor 0.25 … 1.5 mm² / 22 … 16 AWG
Fire load 0.819 MJ
Height 100 mm / 3.937 inches
Housing material Polycarbonate; polyamide 6.6
Indicators LED (1, 2, 9, 10) red/green: operating status C/Q 1 … C/Q 4; LED (8) green: operating status IO-Link master; LED (16) red: group error
Isolation 500 V system/field
Mounting position Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Mounting type DIN-35 rail
Number of incoming power jumper contacts 2
Number of outgoing power jumper contacts 2
Operating altitude 0 … 2000 m / 0 … 6562 ft
Permissible H2S contaminant concentration at a relative humidity < 75 % 10 ppm
Permissible SO2 contaminant concentration at a relative humidity < 75 % 25 ppm
Pollution degree 2 per IEC 61131-2
Protection type IP20
PU (SPU) 1 pcs
Relative humidity (without condensation) 95 %
RoHS Compliance Status Compliant,With Exemption
SCIP notification number (Austria) 6c781b87-021e-4446-a85e-2e4e7f568cda
SCIP notification number (Belgium) 24693d0d-4d13-4c9f-a2b7-26b17625640d
SCIP notification number (Bulgaria) 26741315-2d60-4e6b-acde-dd1f51c6844f
SCIP notification number (Czech Republic) d857c101-3687-4f6a-aea0-47edf367fa6c
SCIP notification number (Denmark) 27796915-d29b-4b6f-8f96-761adc16f981
SCIP notification number (Finland) ea18bc28-d025-406f-a077-5ebbc2ca3287
SCIP notification number (France) b016b33e-9a9e-44e5-a56d-5ae098ebb464
SCIP notification number (Germany) 49d65735-8bb6-4640-918a-f11148fb0ee7
SCIP notification number (Hungary) a3954213-7f9c-44b0-b62e-8ade40adbbdc
SCIP notification number (Italy) eb1cf1f0-d590-4c1e-93b9-417e9d87a84b
SCIP notification number (Netherlands) 9b97d7ad-2cf1-4720-b7bf-dd1d9db1afb1
SCIP notification number (Poland) 4e208c06-0cae-4277-ad92-4243941212e9
SCIP notification number (Romania) bdca249d-5222-4140-bf1f-af060323c340
SCIP notification number (Sweden) ecea7f67-cb59-4dd9-8420-79365dd6c946
Sensor connection 4 x (3-wire)
Shock resistance 15g per IEC 60068-2-27
Solid conductor 0.08 … 1.5 mm² / 28 … 16 AWG
Strip length 8 … 9 mm / 0.31 … 0.35 inches
Supply voltage (field) 24 VDC (-15 … +20 %); via power jumper contacts (power supply via blade contact; transmission (field side supply voltage only) via spring contact)
Supply voltage (system) 5 VDC; via data contacts
Topology Number of IO-Link ports: 4
Transmission modes 4.8 kBaud (COM 1), 38.4 kBaud (COM 2), 230.4 kBaud (COM 3)
Unspsc 32,151,705
Width 12 mm / 0.472 inches