Browse categories
Phoenix Contact FL SWITCH 1605 M12 Industrial Ethernet Switch
Description
Phoenix Contact FL SWITCH 1605 M12 industrial Ethernet switch offers 5 M12 ports for 10/100 Mbps connections and is rated IP65.
Specifications
| Brand | Phoenix Contact |
|---|---|
| Model | FL SWITCH 1605 M12 |
| Order Number | 2700200 |
| HS Code | 851762 |
| Power supply connection | via M12 connector |
| Supply voltage range | 9 V DC ... 32 V DC |
| Transmission speed | 10/100 Mbps |
| Degree of protection | IP65 |
| Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
| REACH candidate substance (CAS No.) | Lead (CAS: 7439-92-1) |
| Additional functions | Autonegotiation |
| Air pressure (operation) | 86 kPa ... 108 kPa (2000 m above mean sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (3500 m above sea level) |
| Altitude | max. 2000 m (above mean sea level (operation)) |
| Ambient temperature (operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Basic functions | Unmanaged switch/auto negotiation, complies with standard IEEE 802.3, store-and-forward switching mode, 4 priority classes according to IEEE 802.1p, PTCP filter |
| CO2e kg | 20.37 kg CO2e |
| Color (Housing) | black (RAL 9005) |
| Conformance with EMC directives | Noise emission test in accordance with EN 61000-6-3/IEC 61000-6-3 EN 61000-6-3 (noise emission) Class B |
| Conformance with EMC directives | EN 55011 (emitted interference) Class B |
| Conformance with EMC directives | EN 55022 (emitted interference) Class B |
| Conformance with EMC directives | EN 61000-4-2 (ESD) Criterion B |
| Conformance with EMC directives | EN 61000-4-3 (electromagnetic fields) Criterion A, 20 V/m |
| Conformance with EMC directives | EN 61000-4-3 (electromagnetic fields) Criterion A, 10 V/m |
| Conformance with EMC directives | EN 61000-4-4 Criterion A, 2.2 kV |
| Conformance with EMC directives | EN 61000-4-5 (surge) Criterion A, interfaces 1 kV |
| Conformance with EMC directives | EN 61000-4-6 (line noise immunity) Criterion A, Field intensity: 10 V/m |
| Conformance with EMC directives | EN 60950-1 |
| Connection method | M12, shielded |
| Current consumption | 40 mA ... 124 mA (at 24 V DC) |
| Degree of pollution | 2 |
| Degree of protection | IP66 |
| Degree of protection | IP67 |
| Depth | 41 mm |
| Drill hole spacing | 186 mm |
| ECLASS-13.0 | 19170402 |
| ECLASS-15.0 | 19170402 |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Environment friendly use period (EFUP) | EFUP-50 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required. |
| ETIM 10.0 | EC000734 |
| Exemption | 6(c), 7(a), 7(c)-I |
| Fulfills EU RoHS substance requirements | Yes |
| Height | 200 mm |
| Housing material | PBT |
| Local diagnostics | US Supply voltage US Green LED |
| Local diagnostics | X1...X5 Link status Green LED |
| Local diagnostics | X1...X5 Receiving/sending telegrams Green LED |
| Material base plate | High-grade steel (1.4301/1.4016) |
| Max. current consumption | 124 mA |
| Maximum power dissipation for nominal condition | 0.96 W |
| Minimum order quantity | 1 pc |
| Mounting type | Panel mounting |
| Mttf | 302.5 Years (SN 29500 standard, temperature 25°C, operating cycle 21%) |
| MTTF | 156.52 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%) |
| MTTF | 40.43 Years (SN 29500 standard, temperature 55°C, operating cycle 100%) |
| No. of channels | 5 (M12 ports) |
| Noise immunity | EN 61000-6-2 |
| Overvoltage category | II |
| Packing unit | 1 pc |
| Permissible humidity (operation) | 10 % ... 95 % |
| Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
| Product key | DNN114 |
| Product type | Switch |
| PROFINET conformance class | Conformance Class A |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Residual ripple | 3.6 V PP |
| Scip | 47848e5f-3738-4420-8dd5-3bdd7beddecf |
| Shock (operation) | 30g (EN 60068-2-27) |
| Signal LEDs | Data receive, link status |
| Special properties | Extended temperature range |
| Special properties | The product is being prepared for compliance with the Cyber Resilience Act (CRA) |
| Standards/regulations | EN 61000-6-4 |
| Status and diagnostic indicators | LEDs: US (power supply), 2 LEDs per Ethernet port (Link and Activity) |
| Status display | LEDs: US (power supply), 2 LEDs per Ethernet port (Link and Activity) |
| Supply voltage (DC) | 24 V DC (M12 connector) |
| Test section | 24 V supply / functional ground 500 V DC 1 min |
| Test section | Ethernet interface/all other potentials 2.25 kV DC 1 min |
| Transmission length | 100 m (per segment) |
| Transmission medium | Copper |
| Transmission physics | Twisted pair connection |
| Type | Stand-alone |
| Typical current consumption | 40 mA (at U S = 24 V DC) |
| UNSPSC 21.0 | 43222600 |
| Weight per piece (excluding packing) | 220 g |
| Weight per piece (including packing) | 271 g |
| Width | 30 mm |