Skip to content

Beckhoff EK1310 EtherCAT P Extension Module

Beckhoff EK1310 EtherCAT P Extension Module

Request a Quote

Quantity, condition and destination.

Request quote

Description

The Beckhoff EK1310 EtherCAT P extension module provides one P-coded M8 socket for connecting shielded EtherCAT P cable to 100BASE-TX EtherCAT P networks.

Specifications

Brand Beckhoff
Model EK1310
Bus interface 1 x M8 socket, shielded, screw type, P-coded
Power supply external feed-in: 24 V DC (-15%/+20%) for U S and U P
Sum current max. 3 A per U S and U P
Storage temperature -40…+85 °C
Vibration/shock resistance conforms to EN 60068-2-6/EN 60068-2-27
CAS No. 7439-92-1
EMC immunity/emission conforms to EN 61000-6-2/EN 61000-6-4
Approvals/markings CE, UL
Current consumption E-bus typ. 110 mA
Current consumption from U P typ. 3 mA
Current consumption from U S typ. 3 mA
Current rating per port max. 3 A per U S and U P
Electrical isolation 500 V (supply voltage U S /supply voltage U P /EtherCAT)
Protect. rating/installation pos. IP20/variable
Task within EtherCAT system conversion of the E-bus signals to 100BASE-TX Ethernet for feed-in in the EtherCAT P network
Transmission medium EtherCAT P cable, shielded, to 100BASE-TX EtherCAT P networks