Phoenix Contact FL SWITCH 1005N は Unmanaged Switch 1000 シリーズの産業用 Ethernet スイッチです。 DIN レールに取り付けられます。保護等級は IP30 です。

仕様

Brand Phoenix Contact
Model FL SWITCH 1005N
Order Number 1085039
HS Code 851762
Power supply connection Via COMBICON, max. conductor cross-section 2.5 mm²
Supply voltage range 9 V DC ... 32 V DC
Transmission speed 10/100 Mbps
Degree of protection IP30
Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz
REACH candidate substance (CAS No.) Lead (CAS: 7439-92-1)
Additional functions 100 BASE-TX/100BASE-FX (IEEE 802.3u)
Additional functions Quality of Service (QoS) prioritization (IEEE 802.1p)
Additional functions Energy-efficient Ethernet (IEEE 802.3az)
Additional functions 10Base-T (IEEE 802.3)
Altitude 2000 m (maximum)
Ambient temperature (operation) -10 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Basic functions Unmanaged switch
Basic functions Autonegotiation
Basic functions Store and Forward switching mode
Canada UL 61010-1, UL 61010-2-201, UL 62368-1 Class I, Div. 2, Groups A, B, C, D, T4 Class I, Zone 2, Group IIC, T4
Color (Cover) light gray (RAL 7035)
Color (Housing) gray (RAL 7042)
Conductor cross-section AWG 24 ... 12
Conductor cross-section, flexible 0.2 mm² ... 2.5 mm²
Conductor cross-section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 2.5 mm²
Conductor cross-section, flexible, with ferrule, without plastic sleeve 0.25 mm² ... 2.5 mm²
Conductor cross-section, rigid 0.2 mm² ... 2.5 mm²
Conformance with EMC directives EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
Conformance with EMC directives EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
Conformance with EMC directives EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
Conformance with EMC directives EN 61000-6-2 EN 61000-4-5 (surge) Criterion B
Conformance with EMC directives EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
Conformance with EMC directives EN 61000-6-4 EN 55032 Class A
Conformance with EMC directives EN 61000-6-4 Conducted noise emission EN 55032 Class A
Conformance with EMC directives FCC/CFR 47, Part 15.109 Class A
Connection method RJ45
Connection method Push-in spring connection
Depth 84 mm
ECLASS-13.0 19170402
ECLASS-15.0 19170402
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Environment friendly use period (EFUP) EFUP-50 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
ETIM 10.0 EC000734
Exemption 7(a), 7(c)-I
Fcc Title 47 Part 15 Subpart B:2018 Class A
FCC certificate T190905D11-C
Free from substances that could impair the application of coating In acc. with VW specification
Fulfills EU RoHS substance requirements Yes
Height 117 mm
Housing material Polycarbonate fiber reinforced
Input buffer 768 Kbits
MAC address table 2k
Max. current consumption 110 mA (at 9 V DC)
Maximum power dissipation for nominal condition 0.99 W (at 24 V DC)
Minimum order quantity 1 pc
Mounting type DIN rail mounting
Mttf 167.2 Years (MIL-HDBK-217F standard, temperature 25°C, operating cycle 100%)
MTTF 1627 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTTF 1526 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
No. of channels 5 (RJ45 ports)
Noise immunity EN 61000-6-2:2019
Number of interfaces 5
Output buffer 768 Kbits
Packing unit 1 pc
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
Pluggable yes
Product key DNN116
Product type Switch
PROFINET conformance class Conformance Class A
Residual ripple 3.6 V PP (within the permitted voltage range)
Scip 2cf6e074-8e85-4498-87aa-8a0ef94111a5
Shock (operation) 30g (EN 60068-2-27)
Signal LEDs Data receive, link status
Special properties The product is being prepared for compliance with the Cyber Resilience Act (CRA)
Standards/regulations EN_61000-6-4:2019
Status and diagnostic indicators LEDs: U S, link and activity per port
Status display LEDs: U S, link and activity per port
Stripping length 10 mm
Supply voltage (AC) 24 V AC (50/60 Hz)
Supply voltage (DC) 24 V DC
Supply voltage range 18 V AC ... 30 V AC (50/60 Hz)
Transmission length 100 m (per segment)
Transmission medium Copper
Transmission physics Ethernet in RJ45 twisted pair
Typical current consumption 19 mA (at 24 V DC)
UNSPSC 21.0 43222600
Weight per piece (excluding packing) 131 g
Weight per piece (including packing) 210.1 g
Width 22.5 mm