Aller au contenu

Commutateur Ethernet industriel Phoenix Contact FL SWITCH APL 2224-4A-213-PA

Commutateur Ethernet industriel Phoenix Contact FL SWITCH APL 2224-4A-213-PA

Demander un devis

Quantite, etat et destination.

Demander un devis

Description

Le commutateur Ethernet industriel Phoenix Contact FL SWITCH APL 2224-4A-213-PA possède 2 ports RJ45 pour des connexions à 10/100 Mbps et un indice de protection IP20.

Specifications

Brand Phoenix Contact
Model FL SWITCH APL 2224-4A-213-PA
Order Number 1384244
HS Code 851762
Power consumption 25 W (No-load)
Supply voltage range 22 V DC ... 30 V DC (Redundancy)
Output current ≥ 55.56 mA
Output nominal voltage ≥ 9.6 V DC
Power Class SPAA
Power Class SPBA
Power consumption max. 63 W (24 Class A ports at max. load (22 V DC supply voltage at 70°C))
Transmission speed 10/100 Mbps
Degree of protection IP20
Vibration (operation) 1g, according to EN 60068-2-6
REACH candidate substance (CAS No.) Lead (CAS: 7439-92-1)
Altitude 2000 m (maximum)
Ambient temperature (operation) -40 °C ... 70 °C (horizontal)
Ambient temperature (operation) -40 °C ... 60 °C (vertical)
Ambient temperature (storage/transport) -40 °C ... 85 °C
C/IIB, IIIC 1.5 mH / 1.3 µF
C/IIB, IIIC 1.5 mH
Certificate UL 23 ATEX 2992X
Certificate IECEx UL 23.0028X
Color (Cover) light gray (RAL 7035)
Color (Housing) gray (RAL 7042)
Conductor cross-section AWG 24 ... 12
Conductor cross-section, flexible 0.2 mm² ... 2.5 mm²
Conductor cross-section, rigid 0.2 mm² ... 2.5 mm²
Conformance with EMC directives EN 61000-6-2 EN 61000-4-2 (ESD) Criterion A, ±6 kV contact discharge, ±8 kV air discharge
Conformance with EMC directives EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A, Field intensity: 10 V/m
Conformance with EMC directives EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A, supply lines: ±2 kV, signal/data lines: ±1 kV
Conformance with EMC directives EN 61000-6-2 EN 61000-4-5 (surge) Criterion A, ±1 kV supply line L-PE; ±1 kV supply line N-PE; ±1 kV shielded I/O signal lines for metallic enclosure devices
Conformance with EMC directives EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A, 10 Vrms
Conformance with EMC directives EN 61000-6-2 IEC 61000-4-16 (common mode disturbances) Criterion A: 10V (10 kHz to 150 kHz)
Conformance with EMC directives EN 61000-6-4 EN 55011 (emitted interference) Class A
Connection method RJ45
Connection method SFP
Connection method Screw connection
D/IIA, E, F, G, Class III 2.6 mH / 1.4 µF
D/IIA, E, F, G, Class III 2.6 mH
Degree of pollution 2
Depth 127 mm
Diagnostic functions RMON History
Diagnostic functions LLDP (Link Layer Discovery Protocol)
Diagnostic functions SNMP-Traps
Diagnostic functions N:1-Portmirroring
Diagnostic functions ACD (Address Conflict Detection)
Diagnostic functions SysLog
Diagnostic functions CRC-Surveillance
ECLASS-13.0 19170401
ECLASS-15.0 19170401
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU (Test requirements for NE 21, IEC 61326-7 also considered as per the APL EMC specifications)
Environment friendly use period (EFUP) EFUP-10 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
ETIM 10.0 EC000734
Exemption 7(a), 7(c)-I
Filter functions Quality of Service (8 priority classes)
Filter functions Class of Service
Filter functions DiffServ/DSCP
Filter functions Port prioritization
Filter functions IGMP Snooping/Querier (v1/v2)
Filter functions Auto-Query-Port
Filter functions Extended Multicast Filtering
Fulfills EU RoHS substance requirements Yes
Height 215 mm
Housing material Die-cast aluminum
Housing material PC
Identification  II 3(1) G Ex ic ec [ia Ga] IIC T4 Gc
Identification II (1) D [Ex ia Da] IIIC
Identification Ex ic ec [ia Ga] IIC T4 Gc
Identification [Ex ia Da] IIIC
Identification Ind. Cont. Eq. E238705 also Listed
Identification Ind. Cont. Eq. for haz. loc. E196811
Identification Install in: Class I, Div. 2, Groups A, B, C, D T4
Identification Intrinsically safe outputs for: Class I, Div. 2, Groups A, B, C, D; Class II, Groups E, F, G; Class III; [Ex ia] Haz. Loc.
Identification Class I, Zone 2, AEx ic ec [ia Ga] IIC T4 Gc, [AEx ia Da] IIIC
Identification Ex ic ec [ia Ga] IIC T4 Gc X
Identification [Ex ia Da] IIIC X
IIC 0.15 mH / 0.5 µF
IIC 0.15 mH
IP parameterization DHCP client
IP parameterization DHCP server (pool-based, port-based)
IP parameterization BootP
IP parameterization DCP (Discovery and Configuration Protocol)
MAC address table 8k
Management Web-based management (HTTP/HTTPS)
Management Role-based user management (LDAP, RADIUS)
Management SNMPv1/v2/v3
Max. current consumption 5.75 A
Max. output current I o 279.38 mA
Max. output power P o 1.66 W
Max. output voltage U o 13.23 V
Maximum power dissipation for nominal condition 50 W (24 Class A ports at max. load (22 V DC supply voltage at 70°C))
Minimum order quantity 1 pc
Mounting type Panel mount
Mttf 37.59 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
MTTF 19.62 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
MTTF 11.6 Years (SN 29500 standard, temperature 70°C, operating cycle 100%)
No. of channels 2 (RJ45 ports)
No. of channels 2 (SFP ports)
No. of channels 24 (APL ports)
Noise immunity EN 61000-6-2
Number of interfaces 2
Output current ≥ 100 mA
Output current ≥ 84 mA
Output current ≥ 95 mA
Output nominal voltage ≥ 8.9 V DC
Output nominal voltage ≥ 9.52 V DC
Output power ≥ 0.54 W
Output power ≥ 0.89 W
Output power ≥ 0.739 W
Output power ≥ 0.845 W
Overvoltage category II
Packing unit 1 pc
Permissible humidity (operation) 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)
Pluggable yes
Product key DNN128
Product type Switch
Protection class III (IEC 61140, EN 61140, VDE 0140-1)
Redundancy MRP (Media Redundancy Protocol)
Redundancy RSTP (Rapid Spanning Tree Protocol)
Redundancy Large Tree Support
Redundancy LACP (Link Aggregation Control Protocol)
Redundancy PROFINET S2 system redundancy
Safety-related maximum voltage U m 60 V
Shock (operation) 15g (IEC 600868-2-27)
Signal LEDs Data receive, link status
Special properties PROFIBUS PA field switch
Special properties Zone 2 mountable
Special properties Ex ‘ia’ APL ports
Special properties four uplink ports
Special properties The product is being prepared for compliance with the Cyber Resilience Act (CRA)
Standards/regulations EN 61000-6-4
Stripping length 7 mm
Supply voltage (DC) 24 V DC (Redundancy)
Test section Supply Voltage/spurs 1500 V ACrms
Test section 100BASE-T / Spurs 1500 V ACrms
Test section SFP / Spurs 1500 V ACrms
Test section Spurs / Earth Ground (Housing) 500 V ACrms
Test section Block of Spurs / Block of Spurs 500 V ACrms
Test section Supply / 100BASE-T 2000 V ACrms
Test section 100BASE-T / 100BASE-T 2000 V ACrms
Test section Supply / SFP 1500 V ACrms
Time synchronization SNTP (Simple Network Time Protocol)
Transmission length 100 m (per segment)
Transmission length Depending on the SFP module used
Transmission physics Copper
Transmission physics FO
Transmission speed 100/1000 Mbps (full duplex)
Transmission speed 10 Mbps
UNSPSC 21.0 43222600
Weight per piece (excluding packing) 5,629.6 g
Weight per piece (including packing) 6,096.7 g
Width 270 mm