Aller au contenu

Phoenix Contact ELR H3-IES-PT/500AC-06-IFS démarreur moteur hybride

Phoenix Contact ELR H3-IES-PT/500AC-06-IFS démarreur moteur hybride

Demander un devis

Quantite, etat et destination.

Demander un devis

Description

Phoenix Contact ELR H3-IES-PT/500AC-06-IFS fait partie de la gamme CONTACTRON en tant que démarreur moteur hybride. Il se monte sur rail DIN et présente un indice de protection IP20.

Specifications

Brand Phoenix Contact
Model ELR H3-IES-PT/500AC-06-IFS
Order Number 2905141
Leakage current 0 mA
Response time < 0.5 s
Rated insulation voltage 550 V
Rated surge voltage 6 kV
Switching frequency ≤ 2 Hz (Load-dependent)
Control supply voltage range 19.2 V DC ... 30 V DC
Load current range 75 mA ... 600 mA (see to derating)
Mains frequency 50/60 Hz
Operating voltage range 42 V AC ... 550 V AC
Triggering voltage range 19.2 V DC ... 30 V DC
Degree of protection IP20
REACH candidate substance (CAS No.) Lead (CAS: 7439-92-1)
Altitude ≤ 2000 m
Ambient temperature (operation) -5 °C ... 60 °C (observe derating)
Ambient temperature (storage/transport) -40 °C ... 80 °C
Category code NLDX / NRNT
Certificate PTB 15 ATEX 3000
Certificate NLDX.E228652
Certificate NRNT.E172140
Conductor cross-section AWG 24 ... 14
Conductor cross-section flexible 0.2 mm² ... 2.5 mm²
Conductor cross-section rigid 0.2 mm² ... 2.5 mm²
Connection method Push-in connection
Cooling time 20 min (for auto reset)
Coordination type 1
Degree of pollution 2
Depth 114 mm
Environment friendly use period (EFUP) EFUP-50 An article-related China RoHS declaration table can be found in the download area for the respective article under "Manufacturer declaration". For all articles with EFUP-E, no China RoHS declaration table issued and required.
Error indication Red LED
Exemption 7(a), 7(c)-I
Fla 0.6 A (480 V AC)
Flammability rating according to UL 94 (Housing) V0 (Housing)
Fulfills EU RoHS substance requirements Yes
Group installation 20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
Group installation 30 A (class CC or J, SCCR 100kA (480 V AC), #24 - 14 AWG max, solid and stranded)
Height 107.5 mm
Identification  II (2) G [Ex eb] [Ex db] [Ex pxb]
Identification  II (2) D [Ex tb] [Ex pb]
Identification ≤ 3
Identification 2
Identification e
Input name Enable input
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Safe isolation (IEC 60947-1)
Isolation characteristics between the control input and control supply voltage to auxiliary circuit Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Isolation characteristics between the control input and control supply voltage to auxiliary circuit Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Maximum power dissipation 2.5 W
Maximum power dissipation for nominal condition 0.5 W
Minimum order quantity 1 pc
Minimum power dissipation 0.88 W
Motor starter type Direct starter
Mounting position vertical (horizontal DIN rail, motor output below)
Mounting type DIN rail mounting
Number of phases 3
Operate threshold > 10 A
Operating mode 100% operating factor
Operating voltage display Green LED
Overvoltage category III
Packing unit 1 pc
Product key DK7431
Product type Hybrid motor starters
Protective circuit Surge protection
Protective circuit Reverse polarity protection; Parallel polarity protection diode
Protective circuit Reverse polarity protection
Protective circuit Surge protection; Varistor
Rated actuating current I C 7 mA
Rated actuating voltage U C 24 V DC
Rated control circuit supply voltage U S 24 V DC
Rated control supply current I S 60 mA
Rated operating current I e 0.6 A (AC-51)
Rated operating current I e 0.6 A (AC-53a)
Rated operating voltage U e 500 V AC
Sccr 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
SCCR 5 kA (480 V AC (fuse: 20 A RK5 (standard fault)))
Standards/regulations IEC 60947-1
Standards/regulations EN 60947-4-2
Standards/regulations IEC 61508
Standards/regulations ISO 13849
Status display LED (yellow)
Stripping length 10 mm
Switching level < 5 V DC (For EMERGENCY STOP)
Switching threshold 9.6 V (“0” signal)
Switching threshold 19.2 V (“1” signal)
Trigger characteristic in acc. with IEC 60947-4-2 Class 10
Typical turn-off time < 30 ms
UNSPSC 21.0 25173900
Weight per piece (excluding packing) 285.7 g
Weight per piece (including packing) 290 g
Width 22.5 mm