Aller au contenu

Débitmètre Keyence FD-Q20C - d'occasion

Débitmètre Keyence FD-Q20C - d'occasion

Demander un devis

Quantite, etat et destination.

Demander un devis

Description

Débitmètre Keyence FD-Q20C d'occasion, déposé d'un équipement, avec quelques signes d'usure. Tension d'alimentation : 20-30 V DC.

Specifications

Brand Keyence
Model FD-Q20C
Power supply Power voltage 20 to 30 VDC, ripple (P-P) 10% max, Class2/LPS; Current consumption ≤100 mA (Load current excluded)
Response time 0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s
Supply Voltage 20-30 V DC
Power I/O connector M12 4-pin connector
Power Source LPS or Class2
Weight Approx. 400 g (including mounting bracket)
Ambient temperature -10 to +60 °C, 14 to 140 °F; no freezing
Relative humidity 35 to 85 % RH (No condensation)
Supported fluid temperature 0 to 85°C, 32 to 185°F (No freezing on the pipe surface)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 0.06", 2 hours in each of the X, Y, and Z directions
Analog Output 4-20 mA
Analog output (ch.2) 4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance ≤500 Ω
Current Consumption 300 mA
Display method Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator
Display resolution 0.1/ 1 (Default : 0.1) (L/min)
Display update cycle Approx. 3 Hz
Enclosure rating IP65/IP67 (IEC60529)
External input (ch.2) Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), short-circuit current ≤1.5 mA, input time 20 ms or more
Hysteresis Variable
Integrated flow data storage cycle Save to memory every 10 seconds
Integrated flow unit display 0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L)
Material (Mounting bracket) SUS304/PA/SUSXM7
Material (Sensor main unit) PPS/PES/PBT/SUS303/SUS304/SUSXM7
Material (Sensor surface) Rubber
Maximum rated flow 1/2" (15 A): 60 L/min, 15.9 G/min; 3/4" (20 A): 100 L/min, 26.4 G/min
Memory backup EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)
Output (ch.1/ch.2) Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), NPN/PNP setting switchable,open collector output ≤30 V, max. 100 mA/ch., residual voltage ≤2.5 V
Output 1 100 mA
Output 2 100 mA
Protection circuit Power supply reverse connection protection, power supply surge protection, each output short-circuit protection, each output surge protection
Repeatability 0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.) (Specific to selected response time)
Shock resistance 100 m/s^2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Supported fluids Various liquid [i.e. water (including DI), oils, chemicals, etc.]
Supported pipe diameter 1/2" (15 A), ø18 to ø23 (mm); 3/4" (20 A), ø23 to ø28 (mm)
Supported pipe materials Metal pipe/Resin pipe
Zero cut flow rate 2.5 L/min (Default)