Explorar categorias
Sensor amplificador de fibra óptica Keyence FS-V34P - Usado
Descripcion
Sensor amplificador de fibra óptica Keyence FS-V34P usado. Extraído de equipo.
Especificaciones
| Brand | Keyence |
|---|---|
| Model | FS-V34P |
| Origin | Japan |
| Power voltage (rating) | 12 to 24 VDC ±10 %, Ripple (P-P) ≤10 % |
| Response time | HIGH SPEED: 33 µs; FINE: 250 µs; TURBO: 500 µs; SUPER TURBO: 1 ms; ULTRA TURBO: 4 ms; MEGA TURBO: 16 ms |
| Weight | Approx. 70 g |
| Ambient temperature | -10 to +55 °C (14 to 131 °F); no freezing |
| Relative humidity | 35 to 85 % RH (No condensation) |
| Vibration resistance | 10 to 55 Hz; double amplitude 1.5 mm (0.06 in); 2 h each in X, Y, Z directions |
| Ambient light | Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max. |
| Case material | Polycarbonate |
| Control output | 2 outputs |
| Control output | PNP open-collector 24 V, 100 mA max. *1 (main unit only)/20 mA max. (when the expansion unit(s) is connected), Residual voltage: 1 V max. |
| Detection mode | Light intensity (area detection possible, automatic sensitivity-tracking function provided)/ [Limited light intensity/Count check/Abnormality detection] |
| External input | 1 input |
| External inputy | Input time: 2 ms (ON)/20 ms (OFF) min. *2 |
| Light source LED | Red, 4-element LED (Wavelength: 640 nm) |
| Main unit/Expansion unit | Expansion unit |
| Normal operation | HIGHSPEED: 0, FINE: 4, TURBO/SUPER/ULTRA/MEGA: 8 units |
| Output | PNP |
| Output selection | LIGHT-ON/DARK-ON (switch-selectable) |
| Power consumption | Normal: 830 mW max. (Using 24 V, 35 mA max., using 12 V, 45 mA max.)/ Power saving 660 mW max. (Using 24 V, 27 mA max., using 12 V, 32 mA max.) *3 |
| Shock resistance | 500 m/s²; 3 times each in X, Y, Z directions |
| Size | 30.3 mm (H) x 9.8 mm (W) x 71.8 mm (D) 1.19" (H) x 0.39" (W) x 2.83" (D) |
| Timer function | OFF-delay timer/ON-delay timer/One-shot timer/ON-delay timer + OFF-delay timer/ON-delay timer + One-shot timer, selectable Timer duration selectable: 0.1 ms to 9,999 ms, Maximum error against the setting value: ±10% max. |
| Type | 2-output + 1-input with cable |
| Unit expansion | Up to 16 expansion units can be connected (a total of 17 units). Note that the 2-output type should be counted as two units. |