Kategorien durchsuchen
WAGO 750-8100 Controller PFC100
Beschreibung
Der WAGO 750-8100 Controller PFC100 verfügt über zwei ETHERNET-Schnittstellen und wird auf einer 35-mm-Tragschiene montiert.
Spezifikationen
| Brand | WAGO |
|---|---|
| MPN | 750-8100 |
| Transmission rate | ETHERNET: 10/100 Mbit/s |
| Connection type | System supply |
| Weight | 112 g |
| Vibration resistance | 4g per IEC 60068-2-6 |
| CAS-No. | 1303-86-2; 1317-36-8; 7439-92-1; 79-94-7; 80-43-3; 1303-86-2; 1317-36-8; 7439-92-1 |
| EMC emission of interference | per EN 61000-6-3, marine applications |
| EMC immunity to interference | per EN 61000-6-2, marine applications |
| REACH Candidate List Substance | 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol; Diboron trioxide; Lead; Lead monoxide; Peroxide, bis(1-methyl-1-phenylethyl); Diboron trioxide; Lead; Lead monoxide |
| Ambient temperature (operation) | 0 … +55 °C |
| Ambient temperature (storage) | -25 … +85 °C |
| Color | light gray |
| Communications | Modbus (TCP, UDP); ETHERNET; EtherNet/IPTM Adapter (slave), library for e!RUNTIME; MQTT |
| Configuration options | e!COCKPIT; WAGO-I/O-CHECK; Web-Based Management |
| Conformity marking | CE |
| Connectable conductor materials | Copper |
| Connection technology | 2 x CAGE CLAMP® |
| Connection technology | 1 x Male connector; 4-pole |
| Connection technology | Modbus (TCP, UDP): 2 x RJ-45 |
| CPU | Cortex A8; 600 MHz |
| Data memory | 10 MB Program and data memory (dynamically distributed) |
| Depth | 71.9 mm / 2.831 inches |
| Depth from upper-edge of DIN-rail | 64.7 mm / 2.547 inches |
| Drift – Real Time Clock (25 °C) | 3 ppm |
| Drift – system clock (25 °C) | 20 ppm |
| Eccn | NO US CLASSIFICATION |
| eCl@ss 10.0 | 27-24-26-07 |
| eCl@ss 9.0 | 27-24-26-07 |
| ETHERNET protocols | DHCP; DNS; NTP; FTP; FTPS; SNMP; HTTP; HTTPS; SSH |
| ETIM 10.0 | EC000236 |
| ETIM 9.0 | EC000236 |
| Exposure to pollutants | Per IEC 60068-2-42 and IEC 60068-2-43 |
| Fine-stranded conductor | 0.08 … 1.5 mm² / 28 … 14 AWG |
| Fire load | 1.369 MJ |
| Height | 96.8 mm / 3.811 inches |
| Housing material | Polycarbonate; polyamide 6.6 |
| Indicators | LED (SYS, RUN, I/O, USR) red/green/orange: Status system, program, local data bus, status programmable by user (can be used via CODESYS library) |
| Input and output process image (internal) max. | 1000 words/1000 words |
| Input and output process image (Modbus®) max. | CODESYS V3: 32000 words/32000 words |
| Input current (typ.) at nominal load (24 V) | 300 mA |
| Internal memory (flash) | 256 MB |
| Isolation | 500 V system/field |
| Main memory (RAM) | 256 MB |
| Memory Card Slot | Push-push mechanism; Cover lid (sealable) |
| Mounting position | Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom |
| Mounting type | DIN-35 rail |
| Non-volatile hardware memory | 64 kbyte |
| Non-volatile software memory | 64. kbyte |
| Number of modules per node (max.) | 250 |
| Number of modules without a bus extension (max.) | 64 |
| Operating altitude | without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.) |
| Operating system | Real-time Linux 3.18 (with PREEMPT_RT patch) |
| Permissible H2S contaminant concentration at a relative humidity < 75 % | 10 ppm |
| Permissible SO2 contaminant concentration at a relative humidity < 75 % | 25 ppm |
| Pollution degree | 2 per IEC 61131-2 |
| Program memory | 10 MB (Program and data memory (dynamically distributed)) |
| Programming environment | e!COCKPIT (based on CODESYS V3) |
| Programming languages per IEC 61131-3 | Instruction List (IL); Ladder Diagram (LD); Function Block Diagram (FBD); Continuous Function Chart (CFC); Structured Text (ST); Sequential Function Chart (SFC) |
| Protection type | IP20 |
| PU (SPU) | 1 pcs |
| Relative humidity (without condensation) | 95 % |
| RoHS Compliance Status | Compliant,With Exemption |
| RTC backup time (25 °C) | 7 Tage |
| SCIP notification number (Austria) | 86e8b62e-911c-459a-98d8-7ff46473b92b |
| SCIP notification number (Belgium) | 5e6b457b-d6b0-4dbc-aa51-7de31c87ef9b |
| SCIP notification number (Bulgaria) | f4a7c348-ca3f-4fe5-bd39-f87d6f300726 |
| SCIP notification number (Czech Republic) | e9fc129a-b27c-4f30-b213-d9c9c23992ca |
| SCIP notification number (Denmark) | 315459f8-f98b-4532-8f4f-e30e471f3fe4 |
| SCIP notification number (Finland) | b5b323c5-e7db-4104-b2f3-1f5bc39cee5f |
| SCIP notification number (France) | e6d4234e-40d4-4fb0-bf65-23cc89612056 |
| SCIP notification number (Germany) | 55e7e947-8d4a-4517-af63-22a5745d4b61 |
| SCIP notification number (Hungary) | 86da8dcc-fd0a-436f-8421-c7ccd4c5a409 |
| SCIP notification number (Italy) | 1641cd93-c281-46bd-ab9a-343ce9de3d12 |
| SCIP notification number (Netherlands) | 11678f5f-a0a3-45ea-a359-b52521b6742d |
| SCIP notification number (Poland) | 0bef1cc9-3a64-4092-84c2-55cac985d04b |
| SCIP notification number (Romania) | 04f36959-d23d-40e1-8151-c35f8e93c5a4 |
| SCIP notification number (Sweden) | 4aeaad6a-b505-4078-8e0d-cce4f23a8f75 |
| Shock resistance | 15g per IEC 60068-2-27 |
| Solid conductor | 0.08 … 1.5 mm² / 28 … 14 AWG |
| Strip length | 5 … 6 mm / 0.2 … 0.24 inches |
| Supply voltage (system) | 24 VDC, SELV/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP® connection); External fuse required: 2 A slow-blow |
| Total current (system supply) | 700 mA |
| Transmission medium (communication/fieldbus) | ETHERNET: Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length |
| Visualization | Web-Visu |
| Width | 49.5 mm / 1.949 inches |