Gebrauchtes WAGO 750-343 PLC-Modul, aus Gerät ausgebaut. Schutzart IP20.

Spezifikationen

Brand WAGO
MPN 750-343
Transmission rate 9.6 kBd … 12 MBd
Power supply efficiency (typ.) at nominal load (24 V) 80 %
Connection type System supply
Weight 110.4 g
Vibration resistance 4g per IEC 60068-2-6
CAS-No. 1303-86-2; 1317-36-8; 7439-92-1; 79-94-7; 80-43-3
EMC emission of interference per EN 61000-6-4, marine applications
EMC immunity to interference per EN 61000-6-2, marine applications
REACH Candidate List Substance 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol; Diboron trioxide; Lead; Lead monoxide; Peroxide, bis(1-methyl-1-phenylethyl)
Ambient temperature (operation) 0 … +55 °C
Ambient temperature (storage) -25 … +85 °C
Bus segment length (max.) 1200 m
Color light gray
Communications PROFIBUS
Conformity marking CE
Connectable conductor materials Copper
Connection technology 4 x CAGE CLAMP®
Connection technology 1 x Male connector; 4-pole
Connection technology PROFIBUS: 1 x D-sub 9 socket
Current consumption (system supply) 350 mA
Depth 71.9 mm / 2.831 inches
Depth from upper-edge of DIN-rail 64.7 mm / 2.547 inches
Eccn NO US CLASSIFICATION
eCl@ss 10.0 27-24-26-07
eCl@ss 9.0 27-24-26-07
ETIM 10.0 EC001603
ETIM 9.0 EC001603
Exposure to pollutants per IEC 60068-2-42 and IEC 60068-2-43
Fine-stranded conductor 0.08 … 1.5 mm² / 28 … 16 AWG
Fire load 2.254 MJ
Height 96.8 mm / 3.811 inches
Housing material Polycarbonate; polyamide 6.6
Input and output process image (fieldbus) max. 32 bytes/32 bytes
Input current (typ.) at nominal load (24 V) 260 mA
Mounting position Horizontal left, horizontal right, horizontal top, horizontal bottom, vertical top and vertical bottom
Mounting type DIN-35 rail
Number of fieldbus nodes on master (max.) 125
Number of I/O points 6,000
Number of modules per node (max.) 63
Number of modules without a bus extension (max.) 63
Operating altitude 0 … 2000 m / 0 … 6562 ft
Permissible H2S contaminant concentration at a relative humidity < 75 % 10 ppm
Permissible SO2 contaminant concentration at a relative humidity < 75 % 25 ppm
Pollution degree 2 per IEC 61131-2
Protection type IP20
PU (SPU) 1 pcs
Relative humidity (without condensation) 95 %
RoHS Compliance Status Compliant,With Exemption
SCIP notification number (Bulgaria) 64424fac-aa2b-4c0f-9b58-caea0ae6afa7
SCIP notification number (Czech Republic) df827e60-993f-440b-8379-77542fa65ca1
Shock resistance 15g per IEC 60068-2-27
Solid conductor 0.08 … 1.5 mm² / 28 … 16 AWG
Standard EN 50170
Strip length 5 … 6 mm / 0.2 … 0.24 inches
Supply voltage (system) 24 VDC, SELV/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP® connection); External fuse required: 2 A slow-blow
Total current (system supply) 650 mA
Transmission medium (communication/fieldbus) Cu cable per EN 50170
Transmission time typ. 1 ms (10 couplers; each 32 digital I/O and 12 Mbaud) max. 3.3 ms
Unspsc 32,151,705
Width 49.5 mm / 1.949 inches